{"product_id":"abb-iimpm02-multi-bus-processor-module-bailey-infi-90-series","title":"ABB IIMPM02 MULTI-BUS Processor Module Bailey Infi 90 Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB IIMPM02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIIMPM02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMULTI-BUS PROCESSOR MODULE utilized to execute multi-bus arbitration, central processing, and console communication routing across Bailey Infi 90 Series platforms. This master board manages high-speed internal bus transfers and serial communication lines to monitor system variables in real time. It computes automation logic configurations directly within local memory registers and interfaces via an integrated RS-232-C port to maintain constant data synchronization with external terminal nodes.\u003c\/p\u003e\n\u003ch3\u003eHardware Parametric Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIIMPM02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB (Bailey Infi 90)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSWEDEN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComponent Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-Bus Processor Module \/ CPU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply Rails\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+5 V DC input voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Current Draw\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 A typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSerial Interface Port\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-232-C Console Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature Limits\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity Envelope\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95 % RH non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 W typical thermal footprint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e38.1 x 15.2 x 30.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThis CPU platform interfaces directly with parallel backplane structures to execute data processing tasks at maximum backplane bus communication velocity. The architectural configuration accommodates scalable multi-rack layouts, facilitating complex I\/O density scaling options across interconnected control nodes without inducing communication lag or cycle time extensions. The onboard processor coordinates real-time data flow through individual slots, executing cyclic verification procedures that enforce full firmware flash compatibility across all plugged peripheral modules to ensure continuous loop synchronization.\u003c\/p\u003e\n\u003ch3\u003eTechnical Queries \u0026amp; Engineering Answers\u003c\/h3\u003e\n\u003cp\u003eQ: Does this main processor support unrestricted hot-swap module replacement during active run operations?\u003c\/p\u003e\n\u003cp\u003eA: No. Live hot-swap removal of this primary processor card will instantly interrupt active backplane bus communication velocity across the rack segment. Pulling the CPU during execution halts state-machine monitoring loops and can lead to unpredicted control sequence failures or configuration loss in matching slot devices.\u003c\/p\u003e\n\u003cp\u003eQ: How does a current drop on the +5 V DC logic rail affect the processing core?\u003c\/p\u003e\n\u003cp\u003eA: The board relies on a steady 3 A draw at +5 V DC to sustain internal logic timing. A supply sag below official operational thresholds triggers an internal voltage-monitoring reset circuit, causing the module to cease operations instantly to prevent corrupt configuration data from being transmitted over the network bus.\u003c\/p\u003e\n\u003cp\u003eQ: What are the main configuration requirements for establishing communication through the RS-232-C serial terminal interface?\u003c\/p\u003e\n\u003cp\u003eA: Technicians must ensure that the connecting terminal hardware has identical transmission parameters, matching the processor module speed, parity configurations, and hardware flow control protocols. Incorrect pin assignment or cross-talk on unshielded lines will cause parity faults and suspend configuration terminal logging.\u003c\/p\u003e\n\u003ch3\u003eMechanical Installation and Terminal Grounding\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCard Cage Insertion and Alignment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePlace the circuit card edge boundaries inside the designated cabinet rails. Carefully push the module inward until the rear pins mesh with the backplane distribution block, then tighten the faceplate screws to eliminate mechanical play.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSerial Line Separation Requirements:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the RS-232-C console communication cable through isolated wire ducts separate from industrial high-voltage alternating current pathways to lower the risk of electromagnetic noise induction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrostatic Discharge Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePersonnel must connect a dedicated grounding wrist strap to the bare metallic structure of the control enclosure prior to handling the processor card or modifying any logic jumpers on the board substrate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eComponent Package Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB Bailey Infi 90 IIMPM02 Multi-Bus Processor Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Front Console Port Protective Cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Hardware Jumper Placement Datasheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFreight Despatch Logistics\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish parameters are updated and confirmed within our central node. Dispatches are handled directly from our shipping point in Xiamen, China, utilizing express courier lines such as DHL, FEDEX, or UPS. The 0.8 kg processor assembly is sealed inside a thick anti-static industrial packaging wrap featuring specialized moisture-absorbing packs and fitted tightly into a multi-wall exterior shipping box complete with custom-molded foam protection inserts to insulate the micro-components and backplane connector matrices from mechanical impact during transport.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021144772781,"sku":"IIMPM02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/IIMPM02-1.jpg?v=1779873802","url":"https:\/\/www.maxwellplc.com\/products\/abb-iimpm02-multi-bus-processor-module-bailey-infi-90-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}