{"product_id":"abb-iepaf01-ac-field-power-supply-module-bailey-infi-90-series","title":"ABB IEPAF01 AC Field Power Supply Module Bailey Infi 90 Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB IEPAF01\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEPAF01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Field Power Supply Module, operates as a dedicated hardware component for AC-to-DC power rectification, voltage stabilization, and field excitation distribution within Bailey Infi 90 Series platforms. This module converts wide-range alternating input voltages into a regulated direct current output path to energize field instruments, transmitters, and localized loop networks. It enforces strict galvanic separation between the primary AC utility grid and low-voltage field-side circuitry to suppress common-mode electrical anomalies during continuous operations.\u003c\/p\u003e\n\u003ch3\u003ePhysical and Electrical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEPAF01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB (Bailey Infi 90)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Supply Classification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Field Power Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAC Input Voltage Window\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e120 \/ 240 VAC nominal (+\/-10 % tolerance)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExtended AC Input Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85 to 264 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal DC Output Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+24 VDC at 4.3 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePeak Output Power Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConversion Efficiency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026gt;= 85 % at 230 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature Envelope\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity Threshold\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 to 95 % RH non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Device Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35.6 x 5.1 x 17.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Bus Power Integration and Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThis field power supply module is built to sustain uniform voltage tracks, preventing fluctuations that compromise backplane bus communication velocity across adjacent chassis slots. The +24 VDC output rail supports high I\/O density scaling options by supplying clean loop power to external field termination units directly connected to the system rack. This localized conversion layout eliminates grid induction transients from corrupting parallel data lines, thereby ensuring system-wide firmware flash compatibility procedures execute cleanly without bus voltage interruptions or communication link time-outs.\u003c\/p\u003e\n\u003ch3\u003eTechnical Engineering Inquiries\u003c\/h3\u003e\n\u003cp\u003eQ: What are the hot-swap restriction parameters concerning this power supply module?\u003c\/p\u003e\n\u003cp\u003eA: Live hot-swap extraction is prohibited while the AC input lines are energized or under load conditions. Removing an active supply module draws an electrical arc across the rear connection contacts, which destroys the pin plating and introduces high-frequency noise that disrupts concurrent backplane bus communication velocity.\u003c\/p\u003e\n\u003cp\u003eQ: How does an input voltage dip down to 90 VAC alter the +24 VDC output performance?\u003c\/p\u003e\n\u003cp\u003eA: The module operates across an extended input range of 85 to 264 VAC. If the primary grid sags to 90 VAC, the internal regulation loop preserves the +24 VDC, 4.3 A output parameter without dropping below tolerance thresholds or altering local I\/O density scaling stability.\u003c\/p\u003e\n\u003cp\u003eQ: What protection behavior occurs if the field loop exceeds the 250 W peak power capacity?\u003c\/p\u003e\n\u003cp\u003eA: Exceeding the 250 W peak power limit forces the internal controller into an over-current foldback or hiccup shutdown sequence. This protective execution cuts power to the +24 VDC rail, isolating the internal transformer circuits until the field short-circuit or overload is cleared.\u003c\/p\u003e\n\u003ch3\u003eField Assembly Procedures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Alignment \u0026amp; Insertion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlign the module housing within the structural guide tracks of the power chassis. Push smoothly until the rear power plug seats completely into the mating distribution backplane socket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAC Input Wiring Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminal connections for the 120\/240 VAC primary input must be torqued tightly to eliminate terminal heating. Ensure the incoming ground conductor links directly to the technical earth bus of the cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Dissipation Clearances:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify that top and bottom ventilation openings remain unblocked by wiring bundles. Maintaining unrestricted airflow is necessary to match the factory thermal dissipation profile and prevent over-temperature shutdowns.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Manifest Inventory\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB Bailey Infi 90 IEPAF01 AC Field Power Supply Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Rear Connector Terminal Shroud Insert\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Pin-Out Jumper Mapping Guide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics Shipping Protocols\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish parameters are logged and cleared by our verification unit. Consignments are packed and dispatched from our primary facility in Xiamen, China, via international express networks including DHL, FEDEX, or UPS. The 1.1 kg module is enclosed in a thick anti-static industrial packaging pouch and set within a reinforced cardboard container lined with custom-molded foam cushions to protect the internal high-frequency transformer matrices from transport vibrations.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021144150189,"sku":"IEPAF01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/IEPAF01_3.jpg?v=1779874636","url":"https:\/\/www.maxwellplc.com\/products\/abb-iepaf01-ac-field-power-supply-module-bailey-infi-90-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}