{"product_id":"abb-gjr2372600r1515-87wf01g-e-control-i-o-module-advant-800xa","title":"ABB GJR2372600R1515 87WF01G-E Control I\/O Module Advant-800xA","description":"\u003cp\u003eConfigured for signal management within Advant-800xA platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB GJR2372600R1515\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e87WF01G-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControl I\/O Module) provides direct physical electrical execution. The module manages mixed analog and digital signal streams, utilizing a 10 ms update cycle to interface between field instrumentation and control room processing hardware.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFull Model: GJR2372600R1515\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCatalog Designation: 87WF01G-E\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHardware Type: Control I\/O Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGJR2372600R1515 87WF01G-E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.08 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.5 x 8.5 x 30.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA (+\/- 0.1% accuracy)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUpdate Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eControl Bus Determinism\u003c\/h3\u003e\n\u003cp\u003eThe module supports high-speed deterministic networking, integrating with the ABB Advant backplane bus to ensure synchronized data exchange. It is architected to interface with proprietary Ethernet-based routers, maintaining consistent cycle times required for motor control and process automation. The module’s firmware flash compatibility allows for seamless integration into existing 800xA control schemes, ensuring that I\/O density scaling does not impact overall loop integrity or bus communication velocity.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePrimary module: GJR2372600R1515 Control I\/O Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard package includes basic mounting hardware for cabinet installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupplementary interface cables and terminal block connectors are provided separately based on system configuration requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Ensure the module chassis is connected to a dedicated earth bus to satisfy the 1500 VAC isolation requirement and protect against induced surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Routing: Separate analog signal lines from high-voltage AC power cabling to avoid electromagnetic noise interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Orientation: Install vertically on the DIN-rail to ensure adequate airflow across the heat dissipation surfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWire Termination: Utilize ferrules on all stranded wire terminations to ensure high-integrity connections under thermal cycling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the update cycle limitation?\u003c\/p\u003e\n\u003cp\u003eThe module is designed for a fixed 10 ms update rate to support real-time process monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the module powered?\u003c\/p\u003e\n\u003cp\u003eThe unit accepts 24 VDC inputs, which must be sourced from a regulated industrial power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this module hot-swappable?\u003c\/p\u003e\n\u003cp\u003eAdvant-800xA system architecture requires power cycle validation before physical replacement; consult system-specific manuals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the module coexist with other I\/O types?\u003c\/p\u003e\n\u003cp\u003eYes, the modular design allows for integration with other I\/O cards on the same bus rack, provided the backplane power budget is respected.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the module handle 4-20 mA scaling?\u003c\/p\u003e\n\u003cp\u003eScaling is managed within the 800xA control software configuration; ensure proper termination resistors are used if the loop is non-powered.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs firmware field-upgradeable?\u003c\/p\u003e\n\u003cp\u003eFirmware updates are supported via the Advant-800xA engineering workstation interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the digital input threshold?\u003c\/p\u003e\n\u003cp\u003eThe digital inputs are configured for standard 24 VDC logic levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module provide channel-to-channel isolation?\u003c\/p\u003e\n\u003cp\u003eThe module features system-level 1500 VAC isolation; verify specific channel isolation requirements in high-voltage loop applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231193129133,"sku":"GJR2372600R1515 87WF01G-E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-gjr2372600r1515-87wf01g-e-control-i-o-module-f214hz1qull_13ddd22a-fa0a-4fc5-bb04-e444b64b4f20.jpg?v=1762942437","url":"https:\/\/www.maxwellplc.com\/products\/abb-gjr2372600r1515-87wf01g-e-control-i-o-module-advant-800xa","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}