{"product_id":"abb-dsqc679-3hac028357-001-teach-pendant-flexpendant-series","title":"ABB DSQC679 3HAC028357-001 Teach Pendant FlexPendant Series","description":"\u003cp\u003eThe \u003cstrong\u003eABB DSQC679 3HAC028357-001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDSQC679\u003c\/strong\u003e Teach Pendant, operates as a dedicated hardware component for manual axis jogging, trajectory programming, and real-time motion control execution within ABB IRC5 robot controller networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Identification \u0026amp; Configuration Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Hardware Model\u003c\/strong\u003e: DSQC679\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Reference Model\u003c\/strong\u003e: DSQC-679\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpare Part Number\u003c\/strong\u003e: 3HAC028357-001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Classification\u003c\/strong\u003e: Operator Interface \/ Teach Pendant (FlexPendant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterconnect Interface\u003c\/strong\u003e: Integrated 32.5 ft (approx. 10 m) Cable with 17-Pin Heavy-Duty Connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical \u0026amp; Electrical Technical Data\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSQC679 3HAC028357-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e30.0 cm x 20.0 cm x 12.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e32.5 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e17-Pin Industrial Round Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCommunication Interface \u0026amp; Firmware Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe DSQC679 interface device maintains high communication velocity over the controller bus, delivering deterministic operator inputs and trajectory updates to the main processor. Embedded memory architectures preserve full firmware flash compatibility across IRC5 system software versions. This hardware integration allows flexible I\/O density scaling and continuous diagnostic feedback without introducing latency to safety control loops.\u003c\/p\u003e\n\u003ch3\u003eAssembly Package Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB DSQC679 Teach Pendant Assembly (3HAC028357-001)\u003c\/li\u003e\n\u003cli\u003e1 x Integrated 32.5 ft Interface Cable with 17-Pin Connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSite Integration \u0026amp; Cable Handling Instructions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Alignment\u003c\/strong\u003e: Align the orientation keyways on the 17-pin round connector before pushing it into the controller socket, then fully tighten the threaded locking ring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Strain Relief\u003c\/strong\u003e: Avoid bend radii below 100 mm along the 32.5 ft cable assembly to prevent internal conductor fatigue or shielding degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Protection\u003c\/strong\u003e: Mount the teach pendant on its dedicated wall hanger when not in active use to prevent mechanical shock to the touch screen and housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Plug Restrictions\u003c\/strong\u003e: Verify that safety chain bypass protocols are observed prior to connecting or disconnecting the teach pendant while controller control circuit power is active.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering FAQ \u0026amp; System Integration Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific interface connector is integrated onto the DSQC679 cable assembly?\u003c\/p\u003e\n\u003cp\u003eThe unit features an integrated 32.5 ft (10 m) industrial cable terminated with a 17-pin round bayonet-locking connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the DSQC679 teach pendant be hot-swapped during active robot movement?\u003c\/p\u003e\n\u003cp\u003eDisconnecting the pendant opens the dual-channel hardwired emergency stop circuit, triggering an immediate Category 0 safety stop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is grounding continuity maintained through the 32.5 ft connection cable?\u003c\/p\u003e\n\u003cp\u003eShielding braid surrounding internal signal lines connects directly through the metal shell of the 17-pin connector to cabinet earth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes replacing an existing DSQC679 pendant require re-flashing the controller software?\u003c\/p\u003e\n\u003cp\u003eNo, the pendant updates display graphics and parameters directly from host controller memory upon establishing serial bus communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical package dimensions are required for site transport and storage?\u003c\/p\u003e\n\u003cp\u003eThe packaged hardware unit requires shipping dimensions measuring 30.0 cm in length, 20.0 cm in width, and 12.5 cm in height.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the total combined weight of the DSQC679 unit including its cable?\u003c\/p\u003e\n\u003cp\u003eThe total weight of the teach pendant assembly and attached 32.5 ft cable is 2.18 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat safety mechanisms are integrated directly into the DSQC679 hardware body?\u003c\/p\u003e\n\u003cp\u003eThe hardware integrates a dual-circuit three-position enabling device along with a red mushroom-head emergency stop push button.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat precautions must be taken regarding cable installation near high-voltage lines?\u003c\/p\u003e\n\u003cp\u003eRoute the 32.5 ft pendant cable away from motor power leads and VFD output lines to suppress electromagnetic noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021154734253,"sku":"DSQC679 3HAC028357001","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_dsqc6793hac028357001_1.jpg?v=1787480270","url":"https:\/\/www.maxwellplc.com\/products\/abb-dsqc679-3hac028357-001-teach-pendant-flexpendant-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}