{"product_id":"abb-ci855k01-3bse018106r1-masterbus-300-dual-ethernet-port-kit","title":"ABB CI855K01 3BSE018106R1 MasterBus 300 Dual Ethernet Port Kit","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe ABB CI855K01 3BSE018106R1 operates as a high-integrity MasterBus 300 (MB 300) dual Ethernet communication interface kit engineered for the AC 800M controller platform. This specialized hardware module establishes high-availability, deterministic network connections between System 800xA controllers and legacy Advant OCS assemblies or MasterPiece nodes. By hosting twin integrated RJ45 communication ports, the kit manages full network media redundancy directly at the physical layer, avoiding single points of infrastructure failure during critical process cycles. Control engineers specify the CI855K01 to handle complex peer-to-peer dataset communication across large plant networks, including chemical processing operations, power generation grids, and continuous pulp lines. The module executes protocol formatting and traffic management independently, shielding the main controller CPU from heavy communication tasks and securing steady, uninterrupted data updates for critical real-time interlocking strategies.\u003c\/p\u003e\n\u003ch2\u003eEmbedded Protocol Architecture and Media Redundancy\u003c\/h2\u003e\n\u003cp\u003eThe internal micro-architecture of the CI855K01 communication module optimizes data transfer rates over standard Ethernet infrastructures utilizing the specialized MasterBus 300 network protocol. The interface card coordinates a constant data throughput rating of up to 200 datasets per second, maintaining rapid update intervals across extensive peer-to-peer topologies. The system transmits data at a steady 10 Mbit\/s rate, which matches the required timing patterns of legacy Advant networks while incorporating digital filtering to eliminate packet collisions and signal distortion.\u003c\/p\u003e\n\u003cp\u003eThe built-in dual RJ45 interface relies on automated hardware media-monitoring logic to oversee link integrity across both channels simultaneously. When a network switch or primary interconnection cable suffers damage, the internal network drivers shift active data routing to the standby port within milliseconds. This rapid switchover operates transparently without losing system variable data or disrupting active supervision routines, allowing plant engineers to hot-swap broken cables while the plant maintains full production.\u003c\/p\u003e\n\u003ch2\u003ePhysical Network Interface and Hardware Parameters\u003c\/h2\u003e\n\u003cp\u003eThe technical matrix details the physical properties, operational limitations, and customs registration categories required for panel layout planning and international logistics.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication and Mechanical Attribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Technical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Kit Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCI855K01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFactory Component Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE018106R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Protocol Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMasterBus 300 (MB 300)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Interface Array\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x RJ45 (8-pin Ethernet sockets)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBase Transmission Velocity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 Mbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperational Data Transfer Throughput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 Datasets\/s maximum capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Current Draw\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 mA at 24 V DC system voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Mechanical Protection Class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (according to EN60529, IEC 529)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eActive Operating Temperature Upper Limit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to +55°C (+131°F) without forced cooling\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafe Storage Thermal Spectrum\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAllowed Relative Humidity Limit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% non-condensing relative humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduction Country of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGlobal Customs Tariff Identifier (HS Code)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIndividual Kit Net Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.60 kg (1.32 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDispatched Packaging Sizing Volume\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.5 cm x 16.0 cm x 8.9 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eNetwork Setup and Structural Panel Deployment\u003c\/h2\u003e\n\u003cp\u003eProper physical handling and alignment methods shield the internal CMOS circuits from static damage and guarantee stable communication over the system bus. Snap the CI855K01 interface module securely onto the standard AC 800M controller baseplate assembly, verifying that the multi-pin connector arrays seat squarely without bending the pins. Maintain a continuous clearance path of 30 mm above and below the module housing to allow natural air convection to dissipate internal heat and keep the ambient temperature beneath the +55°C limit.\u003c\/p\u003e\n\u003cp\u003eExecute all external network connections using Category 5e or higher shielded twisted-pair (SFTP) industrial communication cables. Maintain a strict minimum cable bending radius of 45 mm within the wire ways to avoid micro-fractures in the internal copper conductors. Connect the outer silver-plated shielding mesh of the RJ45 data lines directly to the metallic shell of the module socket. This routes high-frequency noise transients away from the communication lines and into the low-impedance master cabinet grounding terminal.\u003c\/p\u003e\n\u003ch2\u003eCross-Platform Synthesis and Environmental Survival\u003c\/h2\u003e\n\u003cp\u003eThe CI855K01 demonstrates excellent environmental resilience inside heavy-industrial automation rooms exposed to constant mechanical vibration and fluctuating power levels. Its rugged plastic enclosure blocks electromagnetic field pollution generated by nearby high-voltage variable speed drives, ensuring stable communications during intense factory activities.\u003c\/p\u003e\n\u003cp\u003eThe communication kit plays a key role in connecting different generations of plant equipment under a single supervisory platform. By converting MB 300 data formats smoothly on the fly, it lets older Advant networks talk directly to modern System 800xA control environments or contemporary Honeywell Experion PKS setups. This close network integration allows operations to pass critical process variables, diagnostic warning codes, and historical trend values directly to central SCADA workstations. This provides complete visibility over old and new plant sections without requiring expensive protocol conversion hardware or custom programming.\u003c\/p\u003e\n\u003ch2\u003eProcurement Allocation and Kit Components\u003c\/h2\u003e\n\u003cp\u003eEvery industrial networking kit supplied through our global logistics channels includes a complete set of components for immediate system integration.\u003c\/p\u003e\n\u003cp\u003eThe standard commercial package contains:\u003c\/p\u003e\n\u003cp\u003e(1) One Brand New ABB CI855K01 3BSE018106R1 MasterBus 300 Interface Module.\u003c\/p\u003e\n\u003cp\u003e(2) Dual matching industrial RJ45 port terminal dust protective caps.\u003c\/p\u003e\n\u003cp\u003e(3) Factory-certified quality control diagnostic and verification certificate.\u003c\/p\u003e\n\u003cp\u003e(4) Technical hardware manual detailing terminal configurations and LED codes.\u003c\/p\u003e\n\u003ch2\u003eGlobal Logistics and Industrial Freight Controls\u003c\/h2\u003e\n\u003cp\u003eProcessing and Shipping Horizon: All orders leave our fulfillment facility within 2-7 days when payment finish, governed by instant warehouse stock check authorization.\u003c\/p\u003e\n\u003cp\u003eWe coordinate all global shipments via premium express air transport lines, using DHL, FedEx, and UPS priority networks to ensure fast, trackable delivery to your facility. To protect the high-speed Ethernet transceivers within the CI855K01 from electrostatic discharge (ESD), our team handles every module under strict protective guidelines. We seal each interface card inside a thick, multi-layer anti-static industrial packaging pouch filled with dedicated desiccant packs to prevent moisture build-up. The sealed pouch is nestled within thick, custom-cut shock-absorbing foam cushions and placed inside a heavy-duty, double-walled rigid industrial shipping box to resist impact and vibration during long-distance international transit.\u003c\/p\u003e\n\u003ch2\u003eIndustrial Communication Diagnostics FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: How can an engineer identify a primary network media breakdown using the faceplate of the CI855K01?\u003c\/p\u003e\n\u003cp\u003eA1: The front faceplate of the CI855K01 incorporates dedicated link and activity status LEDs for each of the two RJ45 ports. A steady green LED indicates a healthy physical connection to the network switch, while rapid flashing indicates active data exchange. If a cable break or port failure occurs on the primary line, its link LED extinguishes immediately, and the module activates a backup indicator while sending an infrastructure fault alarm to the host AC 800M controller.\u003c\/p\u003e\n\u003cp\u003eQ2: Does the CI855K01 require manual software addressing adjustments when swapping a broken unit?\u003c\/p\u003e\n\u003cp\u003eA2: The module's base address and network parameters are determined by the system configuration file designed in Control Builder M. When replacing a broken module, complete a direct physical swap of the hardware card; once the rack reboots, the main AC 800M processor detects the new CI855K01 via the backplane and pushes the existing address and dataset allocation map down across the bus automatically.\u003c\/p\u003e\n\u003cp\u003eQ3: Why is the data rate restricted to 10 Mbit\/s when modern Ethernet systems run at 100 Mbit\/s or higher?\u003c\/p\u003e\n\u003cp\u003eA3: The 10 Mbit\/s transmission speed is a strict requirement of the legacy MasterBus 300 protocol architecture. This deterministic speed maintains timing compatibility with classic Advant OCS and MasterPiece 200 nodes on the network ring. The CI855K01 deliberately limits its physical layer velocity to provide stable, timing-accurate data processing for older equipment without needing complex external bridge units.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021165154477,"sku":"3BSE018106R1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ci855_3bse018106r1.jpg?v=1779096546","url":"https:\/\/www.maxwellplc.com\/products\/abb-ci855k01-3bse018106r1-masterbus-300-dual-ethernet-port-kit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}