{"product_id":"abb-ci830-3bse013252r1-profibus-dp-communication-interface-module","title":"ABB CI830 3BSE013252R1 Profibus DP Communication Interface Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe ABB CI830 (Global Engineering Code: 3BSE013252R1) operates as a high-speed, deterministic PROFIBUS DP-V1 Communication Interface module designed exclusively for the decentralized S800 I\/O subrack system. This robust gateway component serves as the vital physical and intellectual bridge between a primary master controller network and remote distributed I\/O module clusters. It manages continuous, heavy-duty data packet exchanges across demanding processing environments, including oil and gas pipeline terminals, large-scale chemical reaction vessels, and baseload electricity generation stations.\u003c\/p\u003e\n\u003cp\u003eIn complex, automated process plants, network packet jitter or interface latencies compromise real-time monitoring and risk blocking critical shutdown commands. The CI830 interface module counters this risk through its dedicated onboard protocol processor, which handles the localized execution of the PROFIBUS DP-V1 stack up to 12000 kbit\/s without adding calculation burdens to the central controller. The module extracts deep acyclic field diagnostics, device calibration trends, and alarm parameters simultaneously alongside standard cyclic I\/O data. By implementing this authentic S800 system link, engineering managers eliminate communication bottlenecks, secure stable millisecond-level remote tracking, and maximize overall plant asset safety.\u003c\/p\u003e\n\u003ch2\u003eNetwork Architecture and Fieldbus Engine\u003c\/h2\u003e\n\u003cp\u003eThe underlying hardware platform uses an advanced specialized integrated circuit (ASIC) engine engineered specifically to process rapid, error-free serial token transmission frames. The module decouples field wiring hazards from the primary processing logic backplane.\u003c\/p\u003e\n\u003ch3\u003eGalvanic Bus Separation\u003c\/h3\u003e\n\u003cp\u003eTo preserve internal data integrity during severe field grounding faults or lightning surges, the CI830 incorporates severe 500 V DC galvanic isolation from the field terminals directly to the communication bus line. This protective barrier traps electrical noise and shields local S800 module logic.\u003c\/p\u003e\n\u003ch3\u003eDynamic Acyclic Diagnostics\u003c\/h3\u003e\n\u003cp\u003eBy implementing the complete PROFIBUS DP-V1 protocol specification, the interface enables remote configuration and asset management software to poll parameters directly. It routes critical parameter updates, sensor faults, and hardware status flags to the control pulpit in real time.\u003c\/p\u003e\n\u003ch2\u003eSystem Performance and Mechanical Attributes\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification Field\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eCertified Industrial Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Model Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCI830 3BSE013252R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpare Part Identification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE013252R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Protocol Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DP-V1 Cyclic and Acyclic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Data Transmission Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12000 kbit\/s (Auto-Baud Sensing Support)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Input Supply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC ±20%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Current Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 50 mA (Approx. 1.2 W)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eField-to-Bus Isolation Barrier\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e500 V DC Continuous\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Hardware Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Shipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16.8 cm x 8.3 cm x 12.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturing Country of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGlobal Customs Tariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePermissible Ambient Thermal Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to 55 Degrees Celsius\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Defense Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eField Commissioning and Network Wiring Mandates\u003c\/h2\u003e\n\u003cp\u003eMount the CI830 housing firmly onto standard 35mm DIN rails inside the marshalling enclosure, verifying that the module snaps securely into its backplane seat to establish uniform data connections.\u003c\/p\u003e\n\u003ch3\u003eRS-485 Shield Termination\u003c\/h3\u003e\n\u003cp\u003eTechnicians must connect the incoming PROFIBUS trunk line using a certified 9-pin D-subminiature fieldbus plug featuring an integrated switchable termination resistor. Strip and terminate the cable shield braid firmly to the metal shell of the D-sub connector to dissipate high-frequency electromagnetic noise to the cabinet ground.\u003c\/p\u003e\n\u003ch3\u003eModuleBus Power Connections\u003c\/h3\u003e\n\u003cp\u003eSupply the unit with a stable, filtered 24 V DC source away from inductive contactor lines. Install the accompanying TB807 ModuleBus terminator block at the end of the attached I\/O cluster to absorb internal backplane reflections and preserve signal rise times across the local communication rail.\u003c\/p\u003e\n\u003ch2\u003eSystem Resilience and Asset Management Synergy\u003c\/h2\u003e\n\u003cp\u003eThe CI830 module functions smoothly across a broad ambient operating window from -20 up to 55 degrees Celsius, thriving in hot, enclosed remote marshalling cubicles without needing active cooling fans. The circuit board is protected against structural moisture and airborne pollutants typical of coastal chemical facilities.\u003c\/p\u003e\n\u003ch3\u003eFlawless Legacy and System 800xA Cohesion\u003c\/h3\u003e\n\u003cp\u003eThe interface integrates natively with System 800xA, Advant OCS, or third-party PLC master scanners that utilize standard GSD profile files. This comprehensive compatibility allows engineers to seamlessly expand remote I\/O lines or renew legacy interface nodes without modifying active controller application logic or completing expensive hardware redesigns.\u003c\/p\u003e\n\u003ch2\u003eOrdering info\u003c\/h2\u003e\n\u003cp\u003eThe standard factory-certified distributed communication fulfillment kit contains the following items:\u003c\/p\u003e\n\u003cp\u003e(1) Brand New ABB CI830 Profibus DP Communication Interface Module\u003c\/p\u003e\n\u003cp\u003e(2) TB807 ModuleBus Terminator with Power Connection Header\u003c\/p\u003e\n\u003cp\u003e(3) Original Factory Verification and Quality Pass Certificate\u003c\/p\u003e\n\u003ch2\u003eLogistics Tracking and Heavy Industrial Packaging\u003c\/h2\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish. All high-priority communications hardware dispatches from our regional fulfillment centers via premium international carrier networks including DHL, FEDEX, and UPS to guarantee fast, tracked delivery directly to your facility. To safeguard the precise microprocessor elements and sensitive RS-485 transceiver ports from electrostatic damage or shock, each module travels sealed inside multi-layer, custom anti-static industrial packaging complete with thick shock-deflecting cellular cushioning.\u003c\/p\u003e\n\u003ch2\u003eFieldbus Interface Operation FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do you configure the specific node station address on the CI830 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The CI830 features physical, integrated hardware rotary or DIP switches on its front housing plate. Technicians must select a unique station address matching the master DCS configuration scan list before applying 24 V DC logic power to the base unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What visual indication confirms that the CI830 has established a valid connection with the Profibus master?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Check the front panel LEDs; a solid green \"RUN\" light accompanied by a steady green \"COMM\" or status indication confirms an active data exchange loop. A blinking or solid red fault indicator reveals an address mismatch, incorrect baud rate configuration, or missing bus termination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the CI830 handle a mix of both digital and analog S800 modules on the same local cluster?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes, the CI830 acts as a transparent network interface proxy. It gathers data bytes from up to twelve digital and analog S800 I\/O modules on the local ModuleBus cluster, reorganizes the signals into standard Profibus DP frames, and streams them to the master controller smoothly.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021164236973,"sku":"ci830","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3BSE013252R1-3.jpg?v=1779261078","url":"https:\/\/www.maxwellplc.com\/products\/abb-ci830-3bse013252r1-profibus-dp-communication-interface-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}