{"product_id":"abb-c86-94639-tuv-flame-scanner-sensor-module-pcba","title":"ABB C86-94639 TUV Flame Scanner Sensor Module PCBA","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB C86-94639\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC86-94639\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePCBA Sensor Module, operates as a dedicated hardware component for flame detection and signal processing within FlameScanner combustion monitoring systems. This module provides direct physical execution of optical-to-electrical signal conversion, filtering, and logic state reporting for safety-instrumented combustion loops.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe C86-94639 serves as the direct successor to the C86-94613 sensor module. It incorporates specific Front End Filter logic to identify flame frequency and intensity, utilizing the technical reference HTCT321019P0032 to define its operational parameters within the scanner housing assembly.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC86-94639\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.00 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.0 x 10.0 x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApplication Dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTUV Safety Certified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eABB Industrial Control \u0026amp; Drive Communication\u003c\/h3\u003e\n\u003cp\u003eThe C86-94639 utilizes deterministic signal processing paths to ensure that combustion feedback is transmitted to the control panel within the required safety response time. Its architecture supports I\/O density scaling within the scanner head, allowing for consistent signal acquisition regardless of fuel composition. The PCBA integrates high-speed logic gates that interface with the system backplane, ensuring that flame-out detection triggers the fail-safe state execution dictated by the master burner management system (BMS).\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eC86-94639 PCBA sensor module assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTUV certification documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMoisture-controlled, anti-static packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHandling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eApply standard Electrostatic Discharge (ESD) protocols when removing the PCBA from its protective packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid direct contact with the circuit board traces or sensor components to prevent contamination or mechanical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the scanner housing is de-energized before module insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the PCBA precisely with the internal connector pins of the FlameScanner housing to prevent pin deformation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTighten housing fasteners to established torque specifications to maintain environmental sealing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the C86-94639 compatible with C86-94613 scanner housings?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is designed as a direct form-fit-function replacement. No mechanical or electrical modifications are required for the retrofit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of TUV certification?\u003c\/p\u003e\n\u003cp\u003eA: TUV certification confirms the module meets international safety standards for fail-safe performance in hazardous combustion monitoring environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this module monitor multiple fuel types?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The Front End Filter technology is adaptable to the specific spectral characteristics of various industrial fuels, including natural gas and fuel oil.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the module support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: No. Flame scanner modules must be installed with the power to the unit disconnected to prevent damage to the internal logic components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates a module failure?\u003c\/p\u003e\n\u003cp\u003eA: Failure is indicated through the master Burner Management System (BMS) logic, which will register a loss of flame signal or a scanner health fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Should I calibrate the sensor after installation?\u003c\/p\u003e\n\u003cp\u003eA: Standard practice requires a burner sensitivity test and signal threshold verification after any sensor replacement to ensure flame detection accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How should the module be stored?\u003c\/p\u003e\n\u003cp\u003eA: Store the module in a dry, moisture-controlled environment within its original anti-static shielding to prevent oxidation of electronic contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the module require field programming?\u003c\/p\u003e\n\u003cp\u003eA: No. The C86-94639 is a plug-and-play assembly; logic configuration is handled via the master burner management control panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231173828781,"sku":"C86-94639","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-c86-94639-flame-scanner-sensor-module-assembly-lmtu0hadxew_f673049e-5484-4cd4-ba0f-ebc232fe7bbc.jpg?v=1762942286","url":"https:\/\/www.maxwellplc.com\/products\/abb-c86-94639-tuv-flame-scanner-sensor-module-pcba","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}