{"product_id":"abb-ax552-1sap250000r0001-analog-input-output-module-ac500-series","title":"ABB AX552 1SAP250000R0001 Analog Input\/Output Module AC500 Series","description":"\u003cp\u003eThe \u003cstrong\u003eABB AX552 1SAP250000R0001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAX552\u003c\/strong\u003e Analog Input\/Output Module, operates as a dedicated hardware component for analog and digital signal processing within ABB AC500 Series automation platforms. The unit processes field signals across 8 configurable channels, interfacing directly with local terminal bases and controller backplanes. Operating at a nominal process voltage of 24 VDC, the module handles signal acquisition and command execution for process parameters while maintaining short-circuit and overcurrent protection via external fusing.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model\u003c\/strong\u003e: AX552\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrder Code\u003c\/strong\u003e: 1SAP250000R0001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e: AC500 Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTariff Code\u003c\/strong\u003e: 8537101190\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Profile\u003c\/strong\u003e: 8-Channel Analog \/ Configurable I\/O Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAX552 1SAP250000R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.8 cm x 2.8 cm x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.5 cm x 7.0 cm x 7.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC (-15%, +20%) \/ Max. 0.15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (UP)\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage Ripple\u003c\/td\u003e\n\u003ctd\u003e5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUP External Line Fuse\u003c\/td\u003e\n\u003ctd\u003e10 A fast-acting fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e8 channels per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Level\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ Standard Analog Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eAC500 Terminal Base I\/O Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB AX552 1SAP250000R0001\u003c\/strong\u003e connects directly to the AC500 terminal base system, utilizing high-speed internal bus extension protocols to ensure deterministic cyclic scanning across all 8 configurable channels. High-density channel layout allows flexible mixed I\/O configurations while limiting backplane power draw. Field-side isolation guards internal bus circuitry against line-induced voltage spikes. Microprocessor-driven onboard signal processing maintains fast conversion cycles and low latency communication with the AC500 CPU, preserving firmware flash compatibility and scan synchronization across local and decentralized I\/O clusters.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x ABB AX552 1SAP250000R0001 Module Unit\u003c\/li\u003e\n\u003cli\u003e1x Printed Terminal Base Compatibility Guide\u003c\/li\u003e\n\u003cli\u003e1x Factory Quality Inspection Certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Snap the module directly onto a compatible TU5xx Terminal Base attached to a 35 mm DIN rail. Secure mechanical latching clips to maintain proper pin alignment with backplane connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Connect process supply voltage (24 VDC) and channel field devices using screw or spring-clamp terminals on the terminal base. Install a 10 A fast-acting fuse on the UP power supply line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Ensure the DIN rail is electrically bonded to the functional ground (FG) plate using a heavy-duty copper braid or conductor. Ground resistance must measure under 100 ohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding\u003c\/strong\u003e: Use 360-deg braid-shielded twisted-pair cables for analog signal paths. Terminate cable shielding at the designated shield grounding clips on the terminal base.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum allowed ripple voltage on the 24 VDC process supply line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 24 VDC process voltage (UP) must not exceed a maximum AC voltage ripple of 5 % to maintain conversion accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of external fuse protection is required on the UP power line?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe UP supply line requires an external fast-acting fuse rated for a maximum current of 10 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow many total configurable channels are provided on the AX552 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe AX552 module contains 8 independent channels configurable for input\/output operational modes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module attach directly to the DIN rail or through a base component?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module mounts onto an AC500 TU5xx terminal base, which snaps onto a standard 35 mm DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs hot-swapping supported for the AX552 module under power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHot-swapping is restricted; field power supply UP and backplane power must be disabled before replacing the module to prevent electrical stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the operating voltage range for the AX552 module inputs?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe channel inputs operate at a nominal rating of 24 VDC within standard process tolerance windows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are field signals shielded against electromagnetic interference?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eField wiring must use 360-deg braid-shielded cables anchored to the grounding strip on the terminal base frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat firmware requirement applies to the CPU when adding an AX552 module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe controller CPU firmware version must support the AC500 module hardware revision specified in Automation Builder software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021051154605,"sku":"1SAP250000R0001","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/ax522-1.jpg?v=1789394659","url":"https:\/\/www.maxwellplc.com\/products\/abb-ax552-1sap250000r0001-analog-input-output-module-ac500-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}