{"product_id":"abb-ai810-3bse008516r1-analog-input-module-s800-i-o","title":"ABB AI810 3BSE008516R1 Analog Input Module S800 I\/O","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB 3BSE008516R1\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAI810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Input Module, operates as a dedicated hardware component for 8-channel voltage and current signal acquisition within S800 I\/O and Advant 800xA distributed control system platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAI810\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3BSE008516R1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Family:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eS800 I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAI810 (3BSE008516R1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.08 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.5 x 8.5 x 30.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem-dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 bit\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+\/- 0.1 percent of full scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Integration\u003c\/h3\u003e\n\u003cp\u003eThe AI810 utilizes backplane bus communication velocity parameters designed for deterministic signal processing within ABB DCS environments. The module supports I\/O density scaling, allowing for individual channel configuration of voltage (0-10 V, 2-10 V) and current (0-20 mA, 4-20 mA) loops. Firmware flash compatibility ensures the module remains aligned with the host controller's communication stack, supporting HART protocol transparency for smart instrumentation and diagnostic feedback loops.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) AI810 Analog Input Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDocumentation for terminal unit connection and safety standard compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard module retention and mounting clips for MTU (Module Termination Unit) assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeat the module firmly into a compatible S800 I\/O Module Termination Unit (MTU) until the mechanical locking lever is fully engaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the MTU and DIN rail are correctly grounded to the cabinet common to maintain the 2500 V channel-to-channel isolation effectiveness.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminate field signal wiring according to the specific voltage or current loop requirements; use shielded twisted-pair cables to mitigate electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify that input signal levels do not exceed the 30 V overvoltage threshold to prevent damage to the module internal circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the AI810 hot-swappable?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the module supports hot-swapping within S800 I\/O stations, provided the MTU and safety procedures allow for safe removal without disturbing the backplane power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it require external power for the loop?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module provides power for passive sensors depending on the configuration; verify field loop requirements against the technical manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is channel configuration performed?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChannel parameters are set via the engineering station software associated with the Advant 800xA controller configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the resolution fixed?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the module provides a 12-bit analog-to-digital conversion resolution across all eight channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of HART support?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHART transparency allows for the passage of digital diagnostic data from field devices to the DCS without requiring additional dedicated hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module be used in non-ABB systems?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe AI810 is engineered specifically for use with the S800 I\/O platform and is not verified for third-party control system backplanes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are faults indicated?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFaults, including short circuits or open loops, are communicated through the backplane to the controller and displayed via system diagnostic tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the IP rating?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module housing is rated IP20, suitable for protected cabinet installation in controlled industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231172812973,"sku":"3BSE008516R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-ai810-3bse008516r1-ai810-analog-input-module-pchzz3wjuhe_5a62a0d8-ee33-408d-8de1-aca76534b7a4.jpg?v=1762942275","url":"https:\/\/www.maxwellplc.com\/products\/abb-ai810-3bse008516r1-analog-input-module-s800-i-o","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}