{"product_id":"abb-3bse023675r2-ai845-ea-analog-input-hart-8-channel-s800-i-o-module","title":"ABB 3BSE023675R2 AI845-EA Analog Input HART 8-Channel S800 I\/O Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe ABB AI845-EA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eidentified by part number 3BSE023675R2,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density analog input module designed for the S800 I\/O system,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eprimarily utilized within the Advant 800xA and AC 800M controller architectures.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module provides eight independent channels for the precise acquisition of current and voltage signals.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eA standout feature is its integrated HART (Highway Addressable Remote Transducer) protocol support,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich allows for bidirectional communication with smart field devices.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis enables the transmission of secondary process variables and advanced device diagnostics directly to the Distributed Control System (DCS) without disrupting the primary 4-20mA analog signal.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eEssential Hardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Type:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Input with HART redundancy support (S\/R)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrder Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3BSE023675R2\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChannel Count:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8 Differential Isolated Channels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Range:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0...\u003c\/span\u003e\u003cspan class=\"\"\u003e20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4...\u003c\/span\u003e\u003cspan class=\"\"\u003e20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0...\u003c\/span\u003e\u003cspan class=\"\"\u003e5 V,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1...\u003c\/span\u003e\u003cspan class=\"\"\u003e5 V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eA\/D Resolution:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e12-bit plus sign\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProtocol Integration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHART Pass-through for smart instrument management\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIsolation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eGalvanic isolation between channels and system logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Mass:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e34 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16cm x 15.\u003c\/span\u003e\u003cspan class=\"\"\u003e5cm x 8cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Protection:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for rugged industrial cabinet mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Deployment \u0026amp; Field Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe AI845-EA is extensively applied in process-heavy industries such as oil and gas,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003echemical processing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand pharmaceutical manufacturing.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing its HART capabilities,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eplant operators can perform remote configuration and predictive maintenance on pressure transmitters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eflowmeters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand temperature sensors located in inaccessible or hazardous areas.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn power generation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe module ensures high-accuracy monitoring of boiler and turbine parameters,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhere signal integrity and rapid data refresh rates are critical for safety interlocking.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts redundant (S\/R) capability makes it an ideal choice for high-availability systems where the failure of a single input must not result in process shutdown,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring continuous operation in mission-critical automation loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45518975729837,"sku":"3BSE023675R2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-ai845-ea-3bse023675r2-analog-input-s-r-hart-8-channels-zcv4s2fakdn.jpg?v=1766983634","url":"https:\/\/www.maxwellplc.com\/products\/abb-3bse023675r2-ai845-ea-analog-input-hart-8-channel-s800-i-o-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}