{"product_id":"abb-3bse013281r1-tc514v2-repeater-module-twisted-pair-optical-af100-advant-master","title":"ABB 3BSE013281R1 TC514V2 REPEATER MODULE TWISTED PAIR\/OPTICAL AF100 Advant Master","description":"\u003cp\u003eConfigured for optical-to-electrical signal conversion in Advant Fieldbus 100 networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB 3BSE013281R1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eTC514V2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRepeater Module) provides direct physical\/electrical execution. The module enables bi-directional signal transmission between physical twisted pair copper media and fiber optic cables without introducing protocol-level propagation overhead. It maintains complete physical layer transparency, extending the transmission distance and topology limits of standard industrial network segments while ensuring galvanic isolation between distinct network nodes.\u003c\/p\u003e\n\u003ch3\u003eDevice Parameters and Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTC514V2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpare Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE013281R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdvant Fieldbus 100 (AF100)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface Type A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwisted Pair Copper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface Type B\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOptical \/ Fiber Optic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.32 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17 x 5.7 x 12 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 200 mA at 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8517620050\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Backplane \u0026amp; Firmware Synchronization\u003c\/h3\u003e\n\u003cp\u003eAs an integral component within the Advant Master DCS topology, the module interfaces with the underlying backplane bus communication velocity configurations. The hardware contains internal timing registers mapped to synchronize with the deterministic transmission cycles of the AF100 network. Field-level configuration parameters are held within fixed firmware flash blocks, ensuring that media conversion jitter does not disrupt the time-stamped communication packets required by Advant Controllers. This hardware-level execution suppresses propagation drift, rendering the module transparent to the master controller firmware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Queries \u0026amp; Diagnostics\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swap replacement while the AF100 bus is actively communicating?\u003c\/p\u003e\n\u003cp\u003eA: No. Removing or inserting the module during active bus operations can disrupt line impedance characteristics on the twisted pair segment, causing cyclic redundancy check (CRC) errors or brief bus initialization cycles across the remaining nodes. Power down the segment node before replacement.\u003c\/p\u003e\n\u003cp\u003eQ: How is media propagation delay handled when calculating total network cycle time?\u003c\/p\u003e\n\u003cp\u003eA: The physical transceiver circuits introduce a fixed propagation delay that must be accounted for in the AF100 bus configuration utility. When cascading multiple units, the cumulative hardware latency must be factored into the overall station-to-station response times to prevent token-rotation timeouts.\u003c\/p\u003e\n\u003cp\u003eQ: What is the behavior of the optical port if the twisted pair cable loses continuity?\u003c\/p\u003e\n\u003cp\u003eA: The module operates at the physical layer. If a signal loss or line fault is detected on the twisted pair side, the internal transceiver ceases transmission on the optical link, ensuring that downstream repeaters do not process or amplify standard line noise as valid data frames.\u003c\/p\u003e\n\u003ch3\u003eOn-Site Deployment Requirements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding and Grounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe twisted pair cable shield must be terminated directly to the industrial PE chassis rail via a low-impedance grounding clamp at the entry point of the enclosure. Do not daisy-chain the shield through signal ground pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptical Fiber Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure that the fiber optic cables do not exceed the minimum bend radius specified by the manufacturer (typically 30 mm for static installation). Clean all optical interfaces with lint-free wipes and pure isopropyl alcohol prior to insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower supply wiring must be routed separate from high-voltage AC motor leads or switching inductive loads to minimize electromagnetic interference across the internal power filtering stages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Orientation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMount the hardware vertically onto standard DIN rails to maximize natural convection cooling across the internal enclosure surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePurchasing Specification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB TC514V2 3BSE013281R1 Repeater Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory Test Certificate and Declaration of Conformity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: External fiber optic connectors and twisted pair termination blocks must be ordered separately as individual line items.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics \u0026amp; Shipping Profiles\u003c\/h3\u003e\n\u003cp\u003eDelivery window spans 2-7 days upon successful completion of the payment verification process. All shipments route via international carriers including DHL, FEDEX, or UPS. Instruments are packaged exclusively inside anti-static industrial packaging enclosures accompanied by high-density polyethylene foam inserts to neutralize static discharge and mechanical shock hazards during transit.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021161451693,"sku":"3BSE013281R1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3BSE013281R1_2.jpg?v=1779805536","url":"https:\/\/www.maxwellplc.com\/products\/abb-3bse013281r1-tc514v2-repeater-module-twisted-pair-optical-af100-advant-master","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}