{"product_id":"abb-1khw002356r0001-advant-800xa-power-controller-module","title":"ABB 1KHW002356R0001 Advant 800xA Power Controller Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB 1KHW002356R0001\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eB5LD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower Controller Module, operates as a dedicated hardware component for power regulation and Ethernet-based routing tasks within Advant 800xA DCS network architectures.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1KHW002356R0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(B5LD) represents a specific hardware iteration within the ABB Advant 800xA product line. It is engineered to perform deterministic control tasks and data packet routing to facilitate communication between distributed control nodes.\u003c\/p\u003e\n\u003ch3\u003eOperational Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1KHW002356R0001 (B5LD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 x 19 x 5.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 W (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet \/ Routing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCompliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code 8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Communication\u003c\/h3\u003e\n\u003cp\u003eThis module provides deterministic communication via Ethernet infrastructure, supporting the synchronization of distributed control nodes. Firmware flash compatibility ensures that the B5LD integrates with evolving system software versions, while the internal processing architecture handles routing logic to minimize latency across the control bus. The hardware is designed for integration into standard control cabinet backplanes, maintaining physical signal integrity in high-EMI environments.\u003c\/p\u003e\n\u003ch3\u003eOrder Scope\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1KHW002356R0001 B5LD Controller Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory calibration documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct technical datasheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard mounting clips for cabinet integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Seating\u003c\/strong\u003e: Ensure the module is seated perpendicular to the backplane to prevent pin misalignment during connector engagement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding\u003c\/strong\u003e: Connect the module chassis to the cabinet common ground using a low-impedance copper braid to mitigate high-frequency interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Clearance\u003c\/strong\u003e: Maintain a minimum vertical clearance of 50 mm above and below the module to facilitate passive airflow dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e: Utilize shielded twisted-pair (STP) cabling for all Ethernet ports to maintain communication reliability under high electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary communication function of this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe B5LD functions as an Ethernet router, managing data flow and packet distribution between independent controllers in the Advant 800xA architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSystem design should follow the Advant 800xA cabinet-level power isolation protocols before removing or inserting the module to prevent backplane arcing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the required input voltage for operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit is designed for standard industrial 24 VDC bus power provided by the Advant 800xA power supply modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle thermal dissipation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe enclosure uses an industrial-grade conductive housing to dissipate heat. Ensure ambient temperatures remain below 60 deg C for optimal operational longevity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs firmware configuration required during installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module typically inherits configuration parameters from the system controller upon initial network discovery and handshaking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module communicate with non-ABB hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Ethernet port is designed for standard protocols utilized by the 800xA system; connectivity with third-party hardware depends on the defined network topology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat indicates a successful power-on sequence?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module status LEDs will transition from a boot sequence state to a steady state indicating active network synchronization and heartbeat detection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre there specific cabling restrictions for the Ethernet ports?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaximum segment length is 100 meters for copper Ethernet connections; exceedance of this distance requires industrial-grade media converters or switches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231173370029,"sku":"1KHW002356R0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-1khw002356r0001-b5ld-industrial-controller-module-f4nenefxafu_e5ffc1b5-4c1c-4284-a626-105e3b749694.jpg?v=1762942281","url":"https:\/\/www.maxwellplc.com\/products\/abb-1khw002356r0001-advant-800xa-power-controller-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}