{"product_id":"abb-1khl015545r0001-o4le-control-board","title":"ABB 1KHL015545R0001 O4LE Control Board","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB 1KHL015545R0001\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eO4LE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControl Board, operates as a dedicated hardware component for multi-protocol fieldbus communication processing and mixed-signal I\/O execution within O4LE network architectures. Configured for direct physical data link interface routing, the board orchestrates field signals via embedded PROFIBUS DP, Modbus RTU, and DeviceNet protocols while managing localized analog inputs and optically isolated digital inputs.\u003c\/p\u003e\n\u003ch3\u003eParametric Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1KHL015545R0001 O4LE\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.5 x 6.5 x 12.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLess than 5 W typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC, optically isolated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelay Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 VAC \/ 30 VDC, 2 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Protocols\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DP, Modbus RTU, DeviceNet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Architecture and Firmware Execution\u003c\/h3\u003e\n\u003cp\u003eThe controller relies on a dedicated processing core configured to handle high-velocity network transactions without interfering with baseline control logic tasks. The assembly requires exact firmware flash compatibility verification to maintain simultaneous protocol stacking over fieldbus nodes. This communication layer coordinates variables over the internal backplane bus communication velocity channels, enabling uniform I\/O density scaling options across the physical node cluster. By synchronizing digital filter samples with the network master clock, the board guarantees deterministic latency response configurations under peak data line loads.\u003c\/p\u003e\n\u003ch3\u003ePackaging Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB 1KHL015545R0001 O4LE Control Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e3 x Terminal Block Headers (Pluggable Type)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Terminal Resistance Jumper Pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOn-Site Installation Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatic Discharge Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField technicians must remain connected to a verified earth ground terminal via an ESD protection strap before unpacking or handling the board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCabinet Environment Controls:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain vertical mounting inside an enclosure with free space parameters matching standard subrack profiles to restrict ambient temperature elevations above +55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing and Shielding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFieldbus communication lines (PROFIBUS DP, Modbus RTU, and DeviceNet) must utilize specialized shielded twisted-pair cables. Ground the shield at the enclosure bulkhead entry point to block high-frequency electromagnetic interference. Analog input conductors must be segregated from relay output paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLogistics and Packaging Controls\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFulfillment Cycle:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOrders are packaged and ready for dispatch within 2 to 7 days when payment finish processes complete.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShipping Vectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConsignments are systematically routed worldwide via heavy carriers, specifically DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Armoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModules are packed within sealed anti-static industrial packaging matrices, reinforced with high-density polyurethane shell inserts to neutralize multidirectional vibration forces during global transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Is this control board rated for hot-swap operations under active backplane bus configurations?\u003c\/p\u003e\n\u003cp\u003eA: No. The board does not utilize staggered power trace profiles or dedicated inrush current suppression hardware. Live extraction or insertion while the 24 VDC supply rail is energized can induce backplane voltage spikes, leading to runtime logic corruption or physical damage to adjacent processors.\u003c\/p\u003e\n\u003cp\u003eQ: How is the multi-protocol interface configured on the O4LE board?\u003c\/p\u003e\n\u003cp\u003eA: Protocols (PROFIBUS DP, Modbus RTU, or DeviceNet) are assigned via onboard hardware switches or software parameters that must match the corresponding firmware flash compatibility profile. Only one fieldbus interface can operate as the primary host gateway channel concurrently.\u003c\/p\u003e\n\u003cp\u003eQ: What are the specific electrical limits and protection ratings for the integrated digital input lines?\u003c\/p\u003e\n\u003cp\u003eA: The digital inputs accept a nominal 24 VDC level and are protected by an internal 1500 VAC optical isolation barrier. This decoupling structure blocks transient surge propagation from the external loop into the internal logic core.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021085659309,"sku":"1KHL015545R0001","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/PCBBoard_7.jpg?v=1780478643","url":"https:\/\/www.maxwellplc.com\/products\/abb-1khl015545r0001-o4le-control-board","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}