{"product_id":"abb-086444-001-mprc-scanning-board","title":"ABB 086444-001 MPRC Scanning Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB 086444-001 functions as a high performance MPRC scanning board designed to manage high speed data acquisition and sensor communication within industrial control networks. It resolves the challenge of maintaining low latency data throughput between the physical scanning sensors and the central processing unit in complex Distributed Control Systems. By integrating dual Ethernet ports and specialized HDLC ports, this board provides the necessary bandwidth and redundancy for real time process monitoring. It is particularly effective in high demand environments where the synchronization of sensor data across multiple network channels is critical for system stability and accurate diagnostic visibility.\u003c\/p\u003e\n\u003ch3\u003eEssential Hardware Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e086444-001\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries Identifier\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMPRC Scanning System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComponent Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet Scanning Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual Ethernet and Multiple HDLC Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNetwork Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJ2 Connector and ASPC Host Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIndicators\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eERROR RUN and TX LED Status Lights\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePhysical Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 x 19 x 5.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRegulatory Compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE Mark Standard with Fiberoptic Support\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturing Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDCS Automation Infrastructure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Code Decomposition\u003c\/h3\u003e\n\u003cp\u003eThe technical numbering system for the 086444-001 MPRC provides specific information regarding the hardware revision and functional load:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e086444\u003c\/strong\u003e: This base numerical sequence identifies the unique circuit architecture for the Multi Protocol Remote Controller scanning family.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e001\u003c\/strong\u003e: Denotes the primary hardware revision level. This version is optimized for Ethernet based Smart Platform configurations, ensuring full compatibility with J6 host connectors on the ASPC backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMPRC\u003c\/strong\u003e: Standing for Multi Protocol Remote Controller, this indicates the board's capability to translate various industrial communication protocols, including HDLC and TCP IP, into a unified data stream for the host controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Strategy and Wiring\u003c\/h3\u003e\n\u003cp\u003eTo maintain network integrity and comply with electromagnetic compatibility standards, the following installation protocols are required:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHost Integration\u003c\/strong\u003e: The board must be seated into the ASPC backplane using the J2 and J6 connectors. Ensure the board is fully inserted and the locking screws are secured to maintain a stable ground connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Networking\u003c\/strong\u003e: Utilize the specialized Ethernet Y cable to establish a redundant link between the board and the host. The secondary port should be routed through a shielded grounding block on the cabinet door to minimize interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFiberoptic Connection\u003c\/strong\u003e: For sites requiring CE Mark compliance, use high quality fiberoptic cables equipped with ST connectors. This is essential for maintaining isolated sensor communication over long distances or in high noise areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic Monitoring\u003c\/strong\u003e: Upon power up, verify that the RUN LED remains illuminated and the TX LEDs flash during data exchange. An active ERROR LED indicates a protocol mismatch or a backplane connection fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ Frequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the unused HDLC ports 2 and 3?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn standard Smart Platform configurations, ports 2 and 3 are reserved for future expansion or custom sensor arrays. For most applications, primary sensor communication is handled through port 1 and the Ethernet backbone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this board be used without the fiberoptic ST cable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile the board will function with standard copper connections for internal testing, fiberoptic cabling with ST connectors is required for full industrial compliance and to meet European CE standards in production environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the board handle a failure on one Ethernet channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 086444-001 is designed for redundancy. If data transmission is interrupted on the primary channel, the board automatically routes traffic through the secondary Ethernet interface to ensure continuous process monitoring without system downtime.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45518991261869,"sku":"086444-001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-086444-001-mprc-086444-001-scanning-board-4agbprtyt45.jpg?v=1766984228","url":"https:\/\/www.maxwellplc.com\/products\/abb-086444-001-mprc-scanning-board","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}