{"product_id":"aai135-h50-yokogawa-8-channel-hart-interface-analog-input-module","title":"AAI135-H50 Yokogawa 8-Channel HART Interface Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Yokogawa AAI135-H50 is a high-precision analog input interface designed for the CENTUM VP and CS 3000 control environments. This module is engineered to capture 4 to 20 mA signals from field transmitters with extreme reliability. Featuring eight fully isolated channels, it ensures that signal interference and ground loops are eliminated, maintaining the integrity of critical process data. The \"H\" designation signifies integrated HART communication capabilities, allowing the system to not only monitor the primary process variable but also access secondary variables and diagnostic data from smart field devices. It is fully compatible with dual-redundant configurations, providing the high availability necessary for modern industrial automation.\u003c\/p\u003e\n\u003ch3\u003eCore Engineering Specifications and Hardware Logic\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channel Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 Isolated Channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Capture Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA (Maximum input tolerance up to 25 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupported HART Protocol (Version 5\/6\/7)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Conversion Accuracy:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWithin ±16 µA of the measured value\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInternal Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e290 to 450 Ω during active power states; \u0026gt;500 kΩ when powered down\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for 500 V AC for 1 minute (Field-to-System and Channel-to-Channel)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Latency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 ms data update cycle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRated for G3 harsh environments with an operating range of -20°C to 70°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e360 mA at 5V DC and 450 mA at 24V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Mass:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 0.3 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e130 mm (H) x 32.8 mm (W) x 107.5 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Implementation and Operational Utility\u003c\/h3\u003e\n\u003cp\u003eThe AAI135-H50 is a versatile component found in various high-stakes processing environments. Its primary operational roles include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical Refining:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterfacing with pressure and temperature transmitters where HART diagnostics are essential for predictive maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Control Loops:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eServing as a primary input source in dual-redundant setups to ensure zero downtime in safety-critical applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Instrumentation Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing the HART pass-through feature to configure and calibrate field instruments remotely via the Plant Resource Manager (PRM).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environment Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLeveraging the ISA G3 coating to operate in facilities with corrosive gases or significant temperature fluctuations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AAI135-H50 be used in a non-HART application?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, while the module is specialized for HART communication, it functions perfectly as a standard 4-20 mA analog input module for traditional transmitters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the individual channel isolation on this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Channel-to-channel isolation prevents a failure or electrical surge in one field loop from affecting the other seven channels, significantly increasing the robustness of the entire I\/O segment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which mounting blocks are compatible with this module for wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: This module supports several terminal options including the ATI3S-00 pressure clamp block and the ATI3D-00 dual redundant clamp block, depending on your system architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module suitable for use in offshore or corrosive chemical environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, the AAI135-H50 suffix code indicates it is rated for ISA G3 environments, providing specialized protection against humidity and corrosive atmospheric contaminants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the module behave during a power failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Upon power loss, the input resistance increases to over 500 kΩ, effectively disconnecting the field loop from the internal system circuitry to protect the controller.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45882253967533,"sku":"AAI135-H50","price":1599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/AAI135-H50_1.jpg?v=1775182538","url":"https:\/\/www.maxwellplc.com\/products\/aai135-h50-yokogawa-8-channel-hart-interface-analog-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}