{"product_id":"990-10-xx-01-05-mod-165353-01-bently-nevada-vibration-transmitter-990-series","title":"990-10-XX-01-05 MOD:165353-01 Bently Nevada Vibration Transmitter 990 Series","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 990-10-XX-01-05 MOD:165353-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e990\u003c\/strong\u003e Vibration Transmitter, operates as a dedicated hardware component for converting vibration probe signals into conditioned monitoring outputs within Bently Nevada machinery protection systems.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Details\u003c\/h3\u003e\n\u003cp\u003eThe 990-10-XX-01-05 configuration defines a 990 Series vibration transmitter with a 0-10 mils peak-to-peak full-scale range, selectable system cable length options, DIN rail mounting, and hazardous area approval options. The device requires a +12 to +35 VDC input supply at the transmitter terminal.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-10-XX-01-05 MOD:165353-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e990 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.4 x 5.8 x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in provided data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRequires +12 to +35 VDC input at transmitter terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Range\u003c\/td\u003e\n\u003ctd\u003e0-10 mils pp (0-250 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length Option\u003c\/td\u003e\n\u003ctd\u003e5.0 meters \/ 7.0 meters (16.4 feet \/ 23.0 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eCSA Division 2, ATEX Zone 0, ATEX Zone 2, ABS maritime approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003e23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Signal Conditioning and TSI Interface\u003c\/h3\u003e\n\u003cp\u003eThe 990 Series transmitter processes vibration signals from compatible proximity measurement systems and converts mechanical vibration displacement data into electrical monitoring signals. The transmitter configuration supports machinery vibration measurement loops where signal scaling and output conditioning are required.\u003c\/p\u003e\n\u003cp\u003eThe Bently Nevada monitoring architecture uses calibrated probe sensitivity and gap voltage validation methods to maintain measurement consistency. Eddy-current probe scaling parameters must match the connected probe system to maintain correct vibration amplitude conversion. Proper probe gap adjustment and -10 VDC target gap voltage validation are required when commissioning compatible proximity measurement circuits.\u003c\/p\u003e\n\u003ch3\u003eRotor Dynamics Signal Handling\u003c\/h3\u003e\n\u003cp\u003eThe 990 transmitter provides signal conditioning for vibration measurements associated with rotating machinery monitoring. Installation practices must maintain separation between vibration signal wiring and high-current power conductors to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eThe transmitter wiring arrangement supports continuous vibration data transmission from the sensing element to the monitoring interface. Shield termination and grounding practices must follow the system installation requirements to minimize signal noise and cross-talk effects.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 990-10-XX-01-05 MOD:165353-01 Vibration Transmitter\u003c\/li\u003e\n\u003cli\u003e1 x 990 Series transmitter housing with configured vibration measurement electronics\u003c\/li\u003e\n\u003cli\u003e1 x 35 mm DIN rail mounting clip assembly\u003c\/li\u003e\n\u003cli\u003e1 x Configured approval option set for CSA Division 2, ATEX Zone 0, ATEX Zone 2 and ABS maritime approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the transmitter on a compatible 35 mm DIN rail mounting surface.\u003c\/li\u003e\n\u003cli\u003eConfirm that the enclosure location meets the required hazardous area installation classification.\u003c\/li\u003e\n\u003cli\u003eMaintain sufficient clearance for field wiring access and terminal inspection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupply the transmitter through a +12 to +35 VDC power source connected at the transmitter terminal.\u003c\/li\u003e\n\u003cli\u003eRoute vibration signal cables separately from high-voltage switching conductors.\u003c\/li\u003e\n\u003cli\u003eConnect cable shielding according to the grounding practice of the monitoring system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning Check\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify vibration probe compatibility before operation.\u003c\/li\u003e\n\u003cli\u003eConfirm probe scaling parameters match the connected sensing circuit.\u003c\/li\u003e\n\u003cli\u003eValidate signal polarity and output response during startup testing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions and Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat vibration range does the 990-10-XX-01-05 support?\u003c\/p\u003e\n\u003cp\u003eThe transmitter supports a full-scale vibration range of 0-10 mils peak-to-peak, equivalent to 0-250 um peak-to-peak.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat power supply does this transmitter require?\u003c\/p\u003e\n\u003cp\u003eThe unit requires a +12 to +35 VDC input supply connected directly at the transmitter terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhich mounting method is included with this model?\u003c\/p\u003e\n\u003cp\u003eThis configuration includes 35 mm DIN rail clips for mechanical installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable lengths are supported by this configuration?\u003c\/p\u003e\n\u003cp\u003eThe 990 Series configuration supports system lengths of 5.0 meters and 7.0 meters depending on the selected option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model include hazardous area approvals?\u003c\/p\u003e\n\u003cp\u003eThis configuration includes CSA Division 2, ATEX Zone 0, ATEX Zone 2 and ABS maritime approval options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the transmitter be installed without probe scaling verification?\u003c\/p\u003e\n\u003cp\u003eProbe scaling verification is required to ensure the vibration conversion matches the connected proximity measurement system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat wiring practice is recommended for vibration signal cables?\u003c\/p\u003e\n\u003cp\u003eSignal cables should be separated from high-current wiring, and shielding should follow the monitoring system grounding requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this transmitter provide direct vibration measurement output?\u003c\/p\u003e\n\u003cp\u003eThe unit conditions vibration signals from compatible sensing systems and provides an electrical output for machinery monitoring circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025530409133,"sku":"990-10-XX-01-05 MOD:165353-01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/990-10-XX-01-00163930-0113.jpg?v=1785737559","url":"https:\/\/www.maxwellplc.com\/products\/990-10-xx-01-05-mod-165353-01-bently-nevada-vibration-transmitter-990-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}