{"product_id":"990-10-xx-01-05-bently-nevada-mod-163930-01-vibration-transmitter","title":"990-10-XX-01-05 Bently Nevada MOD: 163930-01 Vibration Transmitter","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Bently Nevada 990-10-XX-01-05 (Modified as 163930-01) is a specialized,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eloop-powered vibration transmitter designed for high-density machinery protection.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis device functions as a self-contained signal conditioner that interfaces directly with 3300 NSv proximity probes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003econverting displacement data into a standardized 4-20 mA analog signal.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy integrating Proximitor technology into a field-mountable housing,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit allows for direct machinery surveillance via a PLC or DCS without the requirement for a separate monitoring rack.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis specific \"MOD\" version is optimized for OEM applications where compact footprints and simplified two-wire wiring architectures are essential for monitoring centrifugal compressors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epumps,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand high-speed motors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eKey Technical Characteristics and Hardware Parameters\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis transmitter is engineered to deliver laboratory-grade signal conditioning within a ruggedized industrial form factor,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003esupporting both continuous monitoring and advanced diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e990-10-XX-01-05\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModification Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e163930-01\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMeasurement Range\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0 to 250 µm (0 to 10 mils) peak-to-peak vibration (Option -10)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOutput Signal\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4 to 20 mA DC,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproportional to the vibration level\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProbe Compatibility\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCalibrated for use with Bently Nevada 3300 NSv Proximity Transducers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDiagnostic Interface\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated coaxial connector and \"PROX OUT\" terminals for raw dynamic signal and gap voltage access\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSafety Logic\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt-in \"Not OK\" and Signal Defeat circuitry to suppress false alarms during probe or cable faults\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCalibration Control\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eNon-interacting zero and span potentiometers for precise field loop adjustment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Configuration\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIncludes 35mm DIN-rail clips for rapid control panel installation (Option -01)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eElectrical Connection\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3-pin MIL-C-5015 top-exit connector interface (Option -05)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Requirements\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e12 to 35 Vdc loop power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Applications and Operational Use Cases\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 990-10-XX-01-05 MOD:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e163930-01 is a critical component for Turbine Supervisory Instrumentation (TSI) and general rotating equipment health trending.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCentrifugal Air Compressors\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eReal-time monitoring of radial shaft vibration to detect rotor unbalance or bearing housing instabilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Service Water Pumps\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProviding an easy-to-integrate 4-20 mA signal for SCADA systems to track long-term mechanical degradation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eIndustrial Fan Systems\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMonitoring vibration on large-scale cooling or ventilation fans in hazardous or remote environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOEM Machine Skids\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eServing as a standard,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecost-effective vibration sensing solution for manufacturers of high-speed rotating equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePredictive Maintenance Programs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUtilizing the dynamic \"Prox Out\" signal to perform FFT frequency analysis using portable data collectors while the primary protection loop remains active.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy implementing this modified 990 series transmitter, facilities can achieve high-fidelity shaft monitoring while significantly reducing the costs associated with cabling and secondary signal conditioning hardware.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518820606125,"sku":"990-10-XX-01-05 MOD: 163930-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-990-10-xx-01-05-mod-163930-01-vibration-transmitter-fzkg4nox4j0.jpg?v=1766979524","url":"https:\/\/www.maxwellplc.com\/products\/990-10-xx-01-05-bently-nevada-mod-163930-01-vibration-transmitter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}