{"product_id":"990-05-xx-01-00-bently-nevada-990-series-vibration-transmitter","title":"990-05-XX-01-00 Bently Nevada 990 Series Vibration Transmitter","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-XX-01-00 MOD:165335-01\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e990-05-XX-01-00 Vibration Transmitter\u003c\/strong\u003e, serves as a fixed-output vibration monitoring module that converts proximity probe dynamic displacement signals into a proportional analog transmission output within the 990 transmitter loop architecture.\u003c\/p\u003e\n\u003cp\u003eConfigured for continuous vibration signal conditioning in 3300 XL compatible measurement chains, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 990-05-XX-01-00 MOD:165335-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e990-05-XX-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVibration Transmitter) provides direct signal scaling and loop-level electrical conditioning for downstream control or monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-01-00 MOD:165335-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10 x 7.4 x 6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoop-powered transmitter (typical 4-20 mA class device behavior)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0-5 mils pp (0-125 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length Options\u003c\/td\u003e\n\u003ctd\u003e5.0 m \/ 7.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eVibration proportional output conditioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Scaling \u0026amp; Signal Conditioning Behavior\u003c\/h3\u003e\n\u003cp\u003eThe 990 transmitter processes eddy-current probe-derived displacement signals through internal linearization circuitry, maintaining proportional scaling across the configured full-scale vibration range. Signal integrity depends on stable probe gap voltage correlation and controlled impedance matching across the sensor-to-transmitter loop.\u003c\/p\u003e\n\u003cp\u003eCross-channel interference suppression is managed through internal filtering stages that stabilize amplitude fluctuation under variable rotor dynamic conditions. The output loop maintains deterministic scaling behavior aligned with standard proximity transducer calibration references.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e990: Vibration transmitter platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Full-scale range 0-5 mils pp (0-125 um pp)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eXX: System length selection placeholder (5.0 m \/ 7.0 m option mapping)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e01: 35 mm DIN rail mounting configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: No agency approval option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMOD:165335-01: Factory modification identifier\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-01-00 MOD:165335-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10 x 7.4 x 6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoop-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eProximity transducer signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eScaled analog vibration signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 × 990-05-XX-01-00 MOD:165335-01 vibration transmitter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDIN rail mounting clip assembly (35 mm standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory calibration configuration for selected system length option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eESD protective packaging for industrial instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe transmitter shall be installed on a grounded 35 mm DIN rail to ensure mechanical stability and reference potential consistency. Signal wiring from proximity probe systems must maintain shield continuity from probe head through to transmitter input terminal.\u003c\/p\u003e\n\u003cp\u003eCable routing must avoid parallel alignment with high-voltage conductors to reduce induced noise coupling. Shield termination is recommended at single-point grounding to prevent loop current artifacts in vibration signal paths.\u003c\/p\u003e\n\u003cp\u003eSystem configuration should confirm correct full-scale selection prior to energization to avoid saturation of internal signal conditioning stages.\u003c\/p\u003e\n\u003ch3\u003eDelivery Information\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish via DHL \/ FEDEX \/ UPS.\u003cbr\u003eAll units are packed in anti-static industrial packaging with reinforced shock-resistant containment suitable for vibration monitoring instrumentation.\u003cbr\u003eShipment handled through controlled export logistics channel from Xiamen hub.\u003c\/p\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 990 transmitter operate without a dedicated proximity probe system?\u003c\/strong\u003e\u003cbr\u003eA: No. The device requires an external eddy-current probe input signal to generate calibrated output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the effect of incorrect system length configuration (5 m \/ 7 m)?\u003c\/strong\u003e\u003cbr\u003eA: Incorrect configuration may result in scaling deviation and reduced linearity across the measurement range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is DIN rail grounding required for stable operation?\u003c\/strong\u003e\u003cbr\u003eA: Yes. DIN rail grounding provides reference stability and reduces common-mode noise coupling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the transmitter support hot-swap replacement?\u003c\/strong\u003e\u003cbr\u003eA: Hot-swap is not supported; removal requires de-energization of the loop to avoid signal transients.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How is signal isolation implemented internally?\u003c\/strong\u003e\u003cbr\u003eA: Internal conditioning stages provide electrical separation between probe input and loop output to reduce interference propagation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026871046317,"sku":"990-05-XX-01-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/990.jpg?v=1780308101","url":"https:\/\/www.maxwellplc.com\/products\/990-05-xx-01-00-bently-nevada-990-series-vibration-transmitter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}