{"product_id":"9761-210-triconex-panel-field-termination-option-tricon-v9-v10","title":"9761-210 Triconex Panel Field Termination Option Tricon v9-v10","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Triconex 9761-210 is a specialized Panel Field Termination Option designed to facilitate high-integrity signal connections within Tricon v9 and v10 Safety Instrumented Systems (SIS).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis component serves as the physical interface between field instrumentation and the Tricon controller's input\/output modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEngineered to provide a secure and organized landing point for field wiring,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 9761-210 ensures that critical process data is transmitted with maximum precision and minimal signal degradation.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts robust construction is specifically tailored for the high-availability requirements of Distributed Control Systems (DCS),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it a fundamental element for maintaining safety loop integrity in volatile industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eCore Engineering Specifications and Hardware Layout\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 9761-210 is built to sustain long-term reliability through superior material selection and specialized electrical pathways.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eNative support for Tricon v9 through v10 TMR (Triple Modular Redundant) architectures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Function:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eExternal Field Termination for cabinet-level signal distribution.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Voltage Interface:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for compatibility with various industrial voltage levels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding standard 220V signal environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProcessing Efficiency:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports high-frequency signal throughput up to 50kHz for rapid data acquisition.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInstallation Interface:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh-density terminal block configuration for secure wire retention.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCustomizable Logic:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFeatures adaptable processing paths to meet specific site-wide signal conditioning requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Parameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eMetric Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9761-210\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eComponent Mass\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.34 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13 x 10.7 x 7.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHS Tariff Code\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Compliance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTUV, UL, CE, CSA (SIL 3 Environments)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eIndustrial Deployment and Process Integration\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 9761-210 is deployed globally in sectors where downtime is not an option and signal accuracy is a prerequisite for safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnergy Production and Grid Stability\u003c\/strong\u003e\u003cspan class=\"\"\u003eIn large-scale power generation facilities,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 9761-210 manages the termination of critical sensor inputs.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts high-frequency response ensures that transient events are captured and reported to the safety logic without delay.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChemical and Petrochemical Processing\u003c\/strong\u003e\u003cspan class=\"\"\u003eThis termination option is utilized in reactor safety systems to bridge field-side pressure and temperature transmitters with the Tricon logic.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts ruggedized design protects the signal path from the corrosive atmospheres typical of refinery settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHigh-Integrity Pressure Protection (HIPPS)\u003c\/strong\u003e\u003cspan class=\"\"\u003eActing as the primary junction for safety-critical inputs,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 9761-210 provides the reliable connectivity needed for HIPPS loops,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that isolation valves are triggered instantly upon sensing an overpressure condition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAutomated Manufacturing and Substation Control\u003c\/strong\u003e\u003cspan class=\"\"\u003eThe module's compact footprint allows for efficient space utilization in crowded electrical cabinets,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efacilitating the integration of new safety loops into existing infrastructure during facility expansions or technology refreshes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":45519044378797,"sku":"9761-210","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/triconex-9761-210-panel-field-termination-option-idvweprijul.jpg?v=1766985682","url":"https:\/\/www.maxwellplc.com\/products\/9761-210-triconex-panel-field-termination-option-tricon-v9-v10","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}