{"product_id":"8c-paona2-honeywell-analog-output-interface-module","title":"8C-PAONA2 Honeywell Analog Output Interface Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Honeywell 8C-PAONA2 is a high-precision signal conversion interface designed specifically for the Experion PKS Series 8 I\/O family.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAs a critical link in the Distributed Control System (DCS) architecture,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module translates digital control logic from the C300 controller into accurate 4-20 mA analog signals required by field instrumentation.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy providing the essential electrical drive for final control elements,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 8C-PAONA2 ensures that setpoint adjustments are executed with micro-scale accuracy.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis hardware is engineered for high-availability environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eoffering a robust platform for managing the proportional control of valves,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eactuators,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand speed controllers in mission-critical industrial loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eTechnical Performance Metrics and Hardware Logic\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 8C-PAONA2 is built to sustain high-resolution output and system stability through the following specifications:\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8C-PAONA2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eI\/O Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-HART Analog Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Platform\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Series 8\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard 4-20 mA current loops\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMultiple isolated high-precision outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMaintenance Profile\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull hot-swap capability for online replacement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReal-time loop monitoring and open-circuit detection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Dimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7 x 14 x 14.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNative Series 8 IOTA (Input Output Termination Assembly)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 class=\"\"\u003eIndustrial Control Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eIn\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eUpstream Oil and Gas Production\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 8C-PAONA2 is vital for managing wellhead pressure and flow rates.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts high-resolution signal conversion allows for the minute adjustment of choke valves,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring optimal extraction rates while maintaining safety parameters.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module’s integrated diagnostics are particularly valuable in remote or unmanned offshore platforms,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eas they can identify field wiring degradation or actuator malfunctions and report them immediately to the central Experion PKS console,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epreventing costly unplanned shutdowns.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eWithin\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eChemical Synthesis and Batch Processing\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis analog output module facilitates the precise dosing of reagents by controlling variable frequency drives (VFDs) and proportional feed valves.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBecause the 8C-PAONA2 is hot-swappable,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003efacility technicians can replace modules during active operations without losing control over the rest of the process rack.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis feature is essential for maintaining the thermal stability of exothermic reactions where continuous cooling and ingredient modulation are required to prevent batch spoilage or safety incidents.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eFor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eThermal Power Plants and Steam Management\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 8C-PAONA2 provides the dependable current loops necessary for modulating boiler feed pumps and turbine governor valves.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module's robust electrical isolation protects the DCS backplane from the high-energy transients and electromagnetic interference common in power generation halls.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy ensuring steady and accurate signal delivery,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 8C-PAONA2 contributes to improved fuel efficiency and stable grid frequency by maintaining tight control over the steam cycle.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518942011565,"sku":"8C-PAONA2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-8c-paona2-dcs-backplane-fffrkbgbs53.jpg?v=1766982478","url":"https:\/\/www.maxwellplc.com\/products\/8c-paona2-honeywell-analog-output-interface-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}