{"product_id":"8110-triconex-high-density-main-chassis-tricon-systems","title":"8110 Triconex High Density Main Chassis Tricon Systems","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Triconex 8110 serves as the primary structural and communication foundation for the Tricon™ safety instrumented system (SIS).\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis High Density Main Chassis is engineered to house the core processing power and critical I\/O modules required for fault-tolerant industrial automation.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAs the central hub of a Triple Modular Redundant (TMR) configuration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 8110 provides the backplane connectivity necessary for localized 2-out-of-3 voting and high-speed data synchronization.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for mission-critical reliability,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis chassis facilitates the integration of main processors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epower supplies,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand communication interfaces,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that safety logic is executed without interruption in the world’s most demanding process environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eCore Architecture and Hardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChassis Capacity\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh-density slot configuration for Main Processors and I\/O modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExpansion Interface\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eEquipped with six RS-485 I\/O expansion bus ports for multi-rack scaling\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCommunication Ports\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDual-channel A\/B\/C port sets for redundant system-wide data exchange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSecurity Control\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated four-position physical keyswitch for mode selection (Run,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProgram,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eStop,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRemote)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundancy Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eNative backplane support for TMR (Triple Modular Redundancy) architecture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Scalability\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with 8111 Expansion Chassis and 8112 Remote Extender Modules (RXM)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEnvironmental Tolerance\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt to withstand industrial shock,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003evibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand EMI\/RFI interference\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Mass\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e06 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChassis Dimensions\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e9.\u003c\/span\u003e\u003cspan class=\"\"\u003e3cm x 30.\u003c\/span\u003e\u003cspan class=\"\"\u003e4cm x 26.\u003c\/span\u003e\u003cspan class=\"\"\u003e5cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCompliance\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports SIL3 and TÜV-certified safety instrumented functions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003ePrimary Industrial Deployments\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 8110 High Density Chassis is the preferred starting point for safety systems in high-risk sectors:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOil and Gas Refining\u003c\/strong\u003e\u003cspan class=\"\"\u003eActing as the centralized control rack for refinery-wide Emergency Shutdown (ESD) systems.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts rugged design ensures the safety logic remains active during seismic events or electrical disturbances common in heavy upstream and downstream operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChemical and Petrochemical Processing\u003c\/strong\u003e\u003cspan class=\"\"\u003eHousing the TMR modules that monitor volatile reaction parameters.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe 8110 provides the reliable communication bus needed to shut down processes safely before hazardous thresholds are reached.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eUtility-Scale Power Generation\u003c\/strong\u003e\u003cspan class=\"\"\u003eServing as the safety backbone for burner management systems (BMS) and turbine overspeed protection.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe chassis allows for hot-swapping modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that power plants maintain high availability without de-energizing the safety loop for maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNuclear Safety Systems\u003c\/strong\u003e\u003cspan class=\"\"\u003eUtilized in reactor protection and auxiliary safety loops where a hardware failure cannot be permitted to compromise the safety perimeter.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe 8110's diagnostic depth and physical security keyswitch meet strict regulatory oversight requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMining and Mineral Extraction\u003c\/strong\u003e\u003cspan class=\"\"\u003eProviding a stable mounting platform for safety controllers in remote,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eharsh environments.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts expansion bus capabilities allow the safety network to grow alongside the facility’s output without requiring a total system overhaul.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":45519059189933,"sku":"8110","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/triconex-8110-high-density-main-chassis-revw4f0tvzu.jpg?v=1766985897","url":"https:\/\/www.maxwellplc.com\/products\/8110-triconex-high-density-main-chassis-tricon-systems","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}