{"product_id":"80173-006-01-abb-scr-interface-modules-power-regulation","title":"80173-006-01 ABB SCR Interface Modules Power Regulation","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB 80173-006-01 is a specialized SCR (Silicon-Controlled Rectifier) Thyristor Interface Module, precision-engineered to serve as the critical nexus between low-voltage control logic and high-power industrial electrical systems. In sophisticated Distributed Control Systems (DCS) and power regulation environments, this board manages the complex task of phase control and gate firing signal synchronization. It acts as the backbone for stable power delivery, ensuring that control commands from your automation hardware are executed with absolute timing accuracy at the high-power thyristor stage.\u003c\/p\u003e\n\u003cp\u003eDesigned to thrive in the demanding environments of heavy industry, the 80173-006-01 provides the robust isolation required to protect sensitive control processors from potential high-voltage feedback or transient interference. Whether it is facilitating precise motor speed adjustments or regulating current in large-scale rectifiers, this module ensures high signal integrity and noise immunity. Its compact footprint and reliable circuit architecture make it a favored choice for both new control cabinet installations and the essential maintenance of legacy power conversion infrastructure, where downtime is simply not an option.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel Identification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80173-006-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eComponent Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSCR Thyristor Interface \/ Gate Drive Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eApplication Field\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePower Conversion and Industrial Motor Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Integration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDCS \/ PLC Peripheral\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput\/Output Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecialized SCR Gate Drive Signals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Purity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-noise immunity circuitry\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic isolation (control to power stage)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.50 × 18.50 × 8.00 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCustoms Code (HS)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Configuration Explanation\u003c\/h3\u003e\n\u003cp\u003eThe 80173-006-01 follows a rigorous design numbering system typical of ABB's power electronics division. The \"80173\" series represents a specialized line of thyristor interface boards specifically optimized for gate triggering applications in high-current power environments. The \"006-01\" suffix indicates the specific gate drive configuration and timing characteristics for this board, ensuring it meets the unique voltage threshold and synchronization requirements of standard industrial SCRs. This model is engineered to be a direct fit for existing ABB control racks, ensuring that maintenance engineers can swap out legacy units with minimal wiring adjustments.\u003c\/p\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThis SCR Interface Module is utilized in sectors where power precision is fundamental to operational safety and efficiency:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Drive Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnables the precise firing angles required for variable speed and torque control in large industrial motor applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAC-to-DC Rectification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides the timing signals necessary for stable power conversion in chemical processing and metal refining.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Inverters:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eManages the inversion process for variable-frequency power delivery, crucial for large-scale energy management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControlled Rectifier Banks:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eActs as the firing signal hub for stacks of power thyristors in smelting and electrolytic production environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe ABB 80173-006-01 is designed to integrate seamlessly into diverse DCS and PLC environments, acting as a universal peripheral for thyristor-based power systems. It is fully compatible with ABB’s suite of industrial control cabinets and is commonly used as a bridge in hybrid systems where legacy power electronics are interfaced with modern automation controllers. Its versatility ensures that it can interface with various firing signal protocols, providing a stable, low-latency command link regardless of the primary system architecture.\u003c\/p\u003e\n\u003ch3\u003eInstallation \u0026amp; Integration Best Practices\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatic Sensitivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlways handle the board using proper ESD (Electrostatic Discharge) procedures, as the gate drive components are highly sensitive to static build-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eKeep gate drive signal wires separate from main power lines to prevent induced noise; use twisted-pair shielded cabling where possible.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the board is firmly secured within its designated rack or cabinet slot to prevent mechanical vibration interference during high-current operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBefore full power-up, use an oscilloscope to verify the firing signal pulse width and timing synchronization relative to the AC phase reference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInspection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePeriodically check the mounting hardware and connectors for signs of thermal degradation or oxidation in harsh industrial atmospheres.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Integrity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced filtering circuitry ensures that gate firing pulses are clean, preventing \"false firing\" which could lead to thyristor damage or power instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe board provides an essential safety barrier between the low-voltage control plane and the high-energy power circuits, safeguarding your control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for space-constrained cabinets, this module packs professional-grade power regulation into a small, durable form factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLong-Term Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eABB’s engineering legacy ensures that this interface board remains a reliable, standardized solution for long-term maintenance of critical power infrastructure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe ABB 80173-006-01 is an active component essential for maintaining the operational longevity of your power regulation systems. When ordering, please confirm the full part number (80173-006-01) to ensure the correct firing signal threshold for your specific SCR bank. Lead times are generally optimized to support maintenance programs. Contact your regional industrial automation representative for volume availability or technical documentation requests.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary role of the 80173-006-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It acts as an interface board between low-voltage control logic and high-power thyristors, ensuring accurate gate triggering and signal synchronization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this board compatible with modern PLC systems?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is designed to interface as a peripheral with various PLC and DCS architectures that control power conversion stages.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module require special installation tools?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, standard industrial mounting hardware is used; however, precise alignment and ESD-safe handling are critical during the installation process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does this board protect my control system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It features galvanic isolation, which creates a vital electrical barrier preventing high-voltage transients from reaching and damaging your control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this be used to replace older interface boards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is often utilized for the maintenance of legacy systems, providing a reliable and exact timing match for older SCR configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the unit shipped with technical documentation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Technical specifications and installation guidelines are included; for advanced programming or integration, refer to your specific control system manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What environments are suitable for this board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It is built for industrial settings, though it should be kept in a cabinet that adheres to standard industrial IP protection to avoid moisture or conductive dust.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should I do if the firing signals are unstable?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Check the phase reference signal and ensure the shield grounds are secure; unstable signals are often a result of EMI rather than board failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231166554285,"sku":"80173-006-01 SCR","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-80173-006-01-scr-scr-thyristor-interface-board-1jdobt4oslx_9932a259-4027-4885-bf39-7bd2cfaea6d2.jpg?v=1762942229","url":"https:\/\/www.maxwellplc.com\/products\/80173-006-01-abb-scr-interface-modules-power-regulation","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}