{"product_id":"6180-flifhlhtjez-allen-bradley-industrial-computer-versaview","title":"6180-FLIFHLHTJEZ Allen-Bradley Industrial Computer VersaView","description":"\u003cp\u003eConfigured for high-speed data processing in industrial automation systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 6180-FLIFHLHTJEZ SER B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e6180-FLIFHLHTJEZ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial Computer) provides direct physical execution of control logic and human-machine interface applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Identification\u003c\/h3\u003e\n\u003cp\u003eThe 6180-FLIFHLHTJEZ SER B is a member of the Allen-Bradley VersaView industrial computer series. It is designed to function as a dedicated compute node for control network platforms, offering high resistance to environmental ingress as specified by NEMA type 1, 12, 13, and 4X standards.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6180-FLIFHLHTJEZ SER B\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.64 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 x 29 x 6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 A (Max load)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 - 32 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNEMA Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1, 12, 13, 4X\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eControl Systems and Deterministic Networking\u003c\/h3\u003e\n\u003cp\u003eThe unit is engineered to support seamless integration with Prototypical EtherNet\/IP deterministic networks, maintaining data synchronization across distributed control systems. Firmware flash compatibility ensures that the operating system and drivers can be updated to accommodate evolving network protocol standards. The architecture supports efficient I\/O density scaling, allowing for centralized management of disparate field controllers without degradation of the primary control bus communication velocity.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 6180-FLIFHLHTJEZ Industrial Computer unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting hardware and gaskets for NEMA sealing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital documentation and standard recovery media.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Mounting: Ensure the enclosure panel is flat and rigid to maintain the NEMA 4X ingress seal integrity during mounting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Wiring: Utilize appropriately gauged cabling for 18-32 VDC input. Ensure common-mode noise suppression by using a dedicated isolated DC power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Secure the computer chassis to a common machine ground using a low-impedance braided strap to mitigate high-frequency ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVentilation: Maintain a 5 cm air clearance around all sides of the unit to ensure passive thermal dissipation does not exceed component ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePort Protection: Use NEMA-rated covers for any unused communication ports to maintain IP\/NEMA ingress protection ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 6180-FLIFHLHTJEZ capable of hot-swapping?\u003c\/p\u003e\n\u003cp\u003eNo. Disconnect all power and communication cabling before performing hardware maintenance or module replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the NEMA 4X seal verified?\u003c\/p\u003e\n\u003cp\u003eThe seal is verified by ensuring the provided gasket is correctly seated and the mounting fasteners are torqued evenly across the perimeter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the input current requirement during peak operation?\u003c\/p\u003e\n\u003cp\u003eThe unit is rated for 12 A at peak load; ensure the upstream circuit breaker is sized to handle this demand without nuisance tripping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the unit support redundant power inputs?\u003c\/p\u003e\n\u003cp\u003eConsult the specific terminal wiring diagram provided with the unit, as power input capability is model-revision dependent.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I upgrade the internal system RAM or storage?\u003c\/p\u003e\n\u003cp\u003eHardware upgrades must be performed using authorized components to ensure the system maintains its thermal and mechanical specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the system restored in the event of software failure?\u003c\/p\u003e\n\u003cp\u003eUse the factory-provided recovery media to re-image the drive; ensure all critical configuration files are backed up externally prior to any re-imaging task.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is an isolated DC power supply required?\u003c\/p\u003e\n\u003cp\u003eIsolated power prevents circulating ground currents between the computer and other industrial modules, which can cause erratic data behavior.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the input voltage exceeds 32 VDC?\u003c\/p\u003e\n\u003cp\u003eExceeding the 32 VDC limit will trigger the internal over-voltage protection and may result in permanent hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066474844333,"sku":"6180-FLIFHLHTJEZ SER B","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/6180-FLIFHLHTJEZ-1.jpg?v=1781603386","url":"https:\/\/www.maxwellplc.com\/products\/6180-flifhlhtjez-allen-bradley-industrial-computer-versaview","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}