{"product_id":"57120001-dp-abb-dsai-110-advant-ocs-analog-input-board","title":"57120001-DP ABB DSAI 110 Advant OCS Analog Input Board","description":"\u003ch3 data-path-to-node=\"0\" class=\"\"\u003e57120001-DP DSAI 110 ABB Advant OCS Analog Input Board\u003c\/h3\u003e\n\u003ch3 data-path-to-node=\"1\" class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-path-to-node=\"2\"\u003e\u003cspan class=\"citation-1112 citation-end-1112\"\u003eThe ABB DSAI 110, part number 57120001-DP, is a specialized analog signal acquisition module designed for the S100 I\/O system within the Advant OCS (Open Control System) framework.\u003c\/span\u003e\u003cspan class=\"\"\u003e \u003c\/span\u003e\u003cspan class=\"citation-1111 citation-end-1111\"\u003eThis module is engineered to provide high-resolution conversion of field-level analog signals into digital data, facilitating precise process regulation and monitoring.\u003c\/span\u003e\u003cspan class=\"\"\u003e As a core component of the MasterPiece 200\/1 and Advant Controller 400 series,\u003c\/span\u003e\u003cspan class=\"\"\u003e the DSAI 110 supports multiple input channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e each capable of handling standardized voltage and current ranges.\u003c\/span\u003e\u003cspan class=\"\"\u003e Its high-speed processing capabilities and integrated filtering ensure that raw data from pressure,\u003c\/span\u003e\u003cspan class=\"\"\u003e flow,\u003c\/span\u003e\u003cspan class=\"\"\u003e and temperature transmitters are delivered to the controller with maximum fidelity and minimal latency,\u003c\/span\u003e\u003cspan class=\"\"\u003e even in electrically volatile industrial environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"3\" class=\"\"\u003eKey Technical Characteristics and Hardware Parameters\u003c\/h3\u003e\n\u003cp data-path-to-node=\"4\"\u003e\u003cspan class=\"\"\u003eThe 57120001-DP DSAI 110 is built for deterministic performance and long-term durability in high-density rack configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"5\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,0,0\"\u003e\u003cspan class=\"citation-1110\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"5,0,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-1110\"\u003eModule Type\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-1110 citation-end-1110\"\u003e Analog Input Board (S100 I\/O)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,1,0\"\u003e\u003cb data-path-to-node=\"5,1,0\" data-index-in-node=\"0\" class=\"\"\u003eIdentification Number\u003c\/b\u003e\u003cspan class=\"\"\u003e 57120001-DP \/ DSAI 110\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,2,0\"\u003e\u003cb data-path-to-node=\"5,2,0\" data-index-in-node=\"0\" class=\"\"\u003eInput Signal Capability\u003c\/b\u003e\u003cspan class=\"\"\u003e Supports 0-10 V,\u003c\/span\u003e\u003cspan class=\"\"\u003e 0-20 mA,\u003c\/span\u003e\u003cspan class=\"\"\u003e and 4-20 mA current loops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,3,0\"\u003e\u003cb data-path-to-node=\"5,3,0\" data-index-in-node=\"0\" class=\"\"\u003eData Resolution\u003c\/b\u003e\u003cspan class=\"\"\u003e High-precision A\/D conversion for granular process oversight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,4,0\"\u003e\u003cspan class=\"citation-1109\"\u003e\u003c\/span\u003e\u003cb data-path-to-node=\"5,4,0\" data-index-in-node=\"0\"\u003e\u003cspan class=\"citation-1109\"\u003eIsolation Protection\u003c\/span\u003e\u003c\/b\u003e\u003cspan class=\"citation-1109 citation-end-1109\"\u003e Galvanic isolation between field inputs and system logic to prevent ground loop interference\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,5,0\"\u003e\u003cb data-path-to-node=\"5,5,0\" data-index-in-node=\"0\" class=\"\"\u003eSystem Integration\u003c\/b\u003e\u003cspan class=\"\"\u003e Direct compatibility with Advant Controller 410,\u003c\/span\u003e\u003cspan class=\"\"\u003e 450,\u003c\/span\u003e\u003cspan class=\"\"\u003e and MasterPiece 200 series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,6,0\"\u003e\u003cb data-path-to-node=\"5,6,0\" data-index-in-node=\"0\" class=\"\"\u003eDiagnostic Reporting\u003c\/b\u003e\u003cspan class=\"\"\u003e Integrated self-test routines and error detection for sensor line health\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,7,0\"\u003e\u003cb data-path-to-node=\"5,7,0\" data-index-in-node=\"0\" class=\"\"\u003eModule Form Factor\u003c\/b\u003e\u003cspan class=\"\"\u003e Compact PCB design for vertical slot installation in S100 I\/O racks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,8,0\"\u003e\u003cb data-path-to-node=\"5,8,0\" data-index-in-node=\"0\" class=\"\"\u003ePhysical Mass\u003c\/b\u003e\u003cspan class=\"\"\u003e 0.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,9,0\"\u003e\u003cb data-path-to-node=\"5,9,0\" data-index-in-node=\"0\" class=\"\"\u003eDimensions\u003c\/b\u003e\u003cspan class=\"\"\u003e 2 x 25 x 24.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"5,10,0\"\u003e\u003cb data-path-to-node=\"5,10,0\" data-index-in-node=\"0\" class=\"\"\u003eOrigin\u003c\/b\u003e\u003cspan class=\"\"\u003e Sweden\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-path-to-node=\"6\" class=\"\"\u003eIndustrial Applications and Operational Use Cases\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003e\u003cspan class=\"\"\u003eThe robust signal conditioning of the DSAI 110 makes it a fundamental choice for heavy industry sectors that require reliable data feedback loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul data-path-to-node=\"8\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,0,0\"\u003e\u003cb data-path-to-node=\"8,0,0\" data-index-in-node=\"0\" class=\"\"\u003ePetrochemical Refineries\u003c\/b\u003e\u003cspan class=\"\"\u003e Acquiring real-time pressure and level data from 4-20 mA transmitters to maintain safe operating parameters in distillation units.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,1,0\"\u003e\u003cb data-path-to-node=\"8,1,0\" data-index-in-node=\"0\" class=\"\"\u003eMetals and Steel Production\u003c\/b\u003e\u003cspan class=\"\"\u003e Interfacing with high-temperature sensors and current transducers in smelting furnaces to optimize energy consumption and product quality.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,2,0\"\u003e\u003cb data-path-to-node=\"8,2,0\" data-index-in-node=\"0\" class=\"\"\u003ePower Utility Management\u003c\/b\u003e\u003cspan class=\"\"\u003e Monitoring various analog parameters in turbine control systems and electrical distribution stations within a DCS network.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,3,0\"\u003e\u003cb data-path-to-node=\"8,3,0\" data-index-in-node=\"0\" class=\"\"\u003eWater Treatment Facilities\u003c\/b\u003e\u003cspan class=\"\"\u003e Collecting pH,\u003c\/span\u003e\u003cspan class=\"\"\u003e turbidity,\u003c\/span\u003e\u003cspan class=\"\"\u003e and flow rate data for automated dosing and filtration control logic.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"8,4,0\"\u003e\u003cb data-path-to-node=\"8,4,0\" data-index-in-node=\"0\" class=\"\"\u003eLegacy System Upgrades\u003c\/b\u003e\u003cspan class=\"\"\u003e Serving as a critical replacement part for maintaining the operational life of established Advant OCS installations,\u003c\/span\u003e\u003cspan class=\"\"\u003e ensuring continued communication between legacy S100 I\/O and modern 800xA control layers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45518981791917,"sku":"57120001-DP","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-dsai-110-57120001-dp-advant-ocs-module-2qv4ate45ri.jpg?v=1766983876","url":"https:\/\/www.maxwellplc.com\/products\/57120001-dp-abb-dsai-110-advant-ocs-analog-input-board","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}