{"product_id":"51405047-175-honeywell-cc-pcf901-control-firewall-interface-module","title":"51405047-175 Honeywell CC-PCF901 Control Firewall Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-548 citation-end-548\"\u003eThe Honeywell CC-PCF901 (Part Number: 51405047-175) is a specialized security and communication hub engineered for the Experion PKS Series C architecture.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-547 citation-end-547\"\u003eFunctioning as a high-performance Control Firewall, this module is the primary gateway for Fault Tolerant Ethernet (FTE) traffic, shielding critical controller-to-controller and controller-to-I\/O communications from external network interference.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"citation-546 citation-end-546\"\u003eIt effectively mitigates the risk of broadcast storms and unauthorized network intrusion, ensuring that real-time process data remains deterministic and secure.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eBy segmenting the control level from the broader plant network, the CC-PCF901 maintains the high availability required for mission-critical Distributed Control Systems (DCS).\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters and Network Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Identification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCC-PCF901\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e51405047-175\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePort Density:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e9-Port Integrated FTE Switch\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Standard:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFault Tolerant Ethernet (FTE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Series:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeries C Control Hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCybersecurity Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEmbedded hardware firewall with storm protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-545\"\u003e\u003c\/span\u003e\u003cstrong\u003eIntegration Support:\u003c\/strong\u003e\u003cspan class=\"citation-545 citation-end-545\"\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with C300 Controllers and Safety Manager L1 devices\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Mass:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnit Dimensions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e7 x 14 x 14.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExport Classification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHS CODE 8537101190\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Security Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-544 citation-end-544\"\u003eThe CC-PCF901 51405047-175 is an indispensable asset for facilities in the oil and gas, power generation, and chemical processing sectors where network downtime translates to safety risks.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIts primary role is to serve as the secure interface for \"Level 1\" network devices, including C300 controllers and Safety Manager units. In a typical SCADA or DCS deployment, this firewall module filters non-essential traffic, preventing general plant Ethernet congestion from impacting high-speed control loops. Its ruggedized design and 9-port configuration allow for the consolidation of multiple FTE links within a single Series C rack, optimizing cabinet space while hardening the system against cyber threats and internal network vulnerabilities.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary purpose of the 9-port FTE configuration on the CC-PCF901?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-543 citation-end-543\"\u003eA: The 9 ports allow for the connection of multiple Series C devices, such as redundant C300 controllers and I\/O Link Modules, into a single secure FTE domain.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis ensures that even if one network path fails, the module maintains a high-availability redundant connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 51405047-175 require complex manual software configuration for the firewall?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the CC-PCF901 is designed as a \"set-and-forget\" industrial appliance. Once integrated into the Experion PKS environment, its security rules are largely optimized for FTE traffic, though advanced management options are available through the Experion configuration tools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be used with third-party Ethernet devices?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-542 citation-end-542\"\u003eA: While it uses standard physical Ethernet connectors, the CC-PCF901 is specifically optimized for Honeywell's proprietary FTE protocol.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eConnecting non-FTE devices is possible but may require specific configuration to ensure the firewall logic does not block standard traffic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does this module protect against \"Broadcast Storms\"?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-541 citation-end-541\"\u003eA: The module contains internal logic that monitors incoming traffic rates.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eIf it detects a surge of broadcast packets that could overwhelm the controller’s CPU, the firewall automatically throttles that traffic, preserving the controller's ability to execute safety logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CC-PCF901 hot-swappable in a live Series C rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is designed for maintenance in active environments. However, because it manages the communication for your controllers, swapping a non-redundant firewall will temporarily interrupt the network path for the connected devices.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518942372013,"sku":"51405047-175","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cc-pcf901-51405047-175-control-firewall-module-g2d4qbasca5.jpg?v=1766982491","url":"https:\/\/www.maxwellplc.com\/products\/51405047-175-honeywell-cc-pcf901-control-firewall-interface-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}