{"product_id":"51405039-175-honeywell-cc-paoh01-hart-analog-output-module","title":"51405039-175 Honeywell CC-PAOH01 HART Analog Output Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe CC-PAOH01 (order number 51405039-175) is a Honeywell analog output module used to generate command signals from a control system to field devices. It is applied where stable analog outputs are required for final control elements and auxiliary equipment, such as valve positioners, I\/P converters, and variable-speed drive analog references. Depending on configuration, the module supports common industrial output types including 4–20 mA current loops and 0–10 V voltage outputs, and it may be used in projects that require HART-enabled device interaction.\u003c\/p\u003e\n\u003cp\u003eThe module is designed for control cabinets in continuous process environments, with diagnostic functions intended to support troubleshooting and reduce time to identify wiring faults.\u003c\/p\u003e\n\u003cp\u003eData correction note\u003cbr\u003eYour source text says “supports current and voltage inputs.” For an analog output module, these are output signal types (not inputs). The product description below corrects this to output behavior.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOutput signal types (configuration dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e4–20 mA current output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0–10 V voltage output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eHART capability: Supported for HART-enabled output loops where applicable (system configuration dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUpdate behavior: Fast loop refresh suitable for process control (typical ~100 ms update stated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: 12-bit class (as provided)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: Typically within ±0.1% to ±0.25% of full scale (depends on range and calibration conditions)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics (typical feature set for this module class)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSelf-test and internal health monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOpen-wire\/loop fault detection for current outputs (wiring dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNon-incendive field power concept support in appropriate installations (system and approvals dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTechnical spec presentation (unordered list format)\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel number: CC-PAOH01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrder number: 51405039-175\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule type: Analog Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApprox. weight: 0.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions (approx.): 7.0 x 14.0 x 14.5 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCountry of origin: USA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEnclosure rating note\u003cbr\u003eThe statement “NEMA 4X \/ IP66” typically applies to an enclosure, not an internal I\/O module. If this module is mounted in a rated cabinet, the overall system rating depends on the enclosure and installation practices.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e4–20 mA control outputs for modulating valves and positioners in DCS environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0–10 V analog commands to drives, actuators, or signal isolators where voltage control is used\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl loops requiring diagnostic visibility for wiring integrity and output verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModernization projects that retain HART field devices while updating cabinet I\/O hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess industries such as refining, chemicals, and power where stable analog actuation is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518949744813,"sku":"51405039-175","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cc-paoh01-51405039-175-analog-output-module-4dcrqmughbn.jpg?v=1766982699","url":"https:\/\/www.maxwellplc.com\/products\/51405039-175-honeywell-cc-paoh01-hart-analog-output-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}