{"product_id":"51309241-175-honeywell-tk-ppd011-experion-ls-battery-extension-module","title":"51309241-175 Honeywell TK-PPD011 Experion LS Battery Extension Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Honeywell TK-PPD011,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epart number 51309241-175,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Power Backup Extension Module designed for the Experion LS (Life Sciences) and Series 8 I\/O architecture.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard consumer backup units,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis industrial-grade module is engineered to provide supplementary power to C300 controllers and Series 8 I\/O modules during primary supply fluctuations or total power failure.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy extending the operational window of volatile memory (RAM),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe TK-PPD011 ensures that critical process data,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ealarm configurations,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand logic states are preserved until the system can be safely transitioned to a backup generator or brought to a controlled shutdown.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is a vital component for maintaining data integrity in regulated industries where power interruptions could lead to significant batch loss or compliance discrepancies.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003ePower Infrastructure and Hardware Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe TK-PPD011 is built with high-reliability power circuitry to manage the charging and discharging cycles of secondary battery cells within a DCS cabinet environment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Class\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBattery Extension \/ RAM Retention Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Compatibility\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell Experion LS and Series 8 Control Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eFunctionality\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eExtends controller memory retention during main power loss\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePower Input Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with both AC and DC cabinet power distribution units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInstallation Design\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ePlug-in architecture for Series 8 IOTA (Input Output Termination Assembly)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConstruction\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRuggedized industrial casing with high-vibration resistance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eComponent Mass\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e36 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Profile\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e3.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm x 14 cm x 14.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTariff Header\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHS Code 8537101190\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Resilience and Deployment Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis battery extension module is a prerequisite for facilities that operate under strict \"zero-downtime\" data requirements and high-availability safety protocols.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePharmaceutical Batch Protection\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eProviding the necessary backup power to preserve recipe parameters and audit trail data in the event of a facility-wide power excursion.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControlled Lab Environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsuring that HVAC and environmental monitoring systems maintained by Experion LS remain synchronized and active during electrical maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCritical Process Shutdowns\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnabling C300 controllers to execute complex, multi-step safe-state sequences after the loss of primary power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy System Modernization\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUpgrading the backup capacity of existing Series 8 control racks to meet updated corporate reliability and uptime benchmarks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRemote Terminal Unit (RTU) Support\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBolstering the power stability of control nodes located in areas with unreliable grid infrastructure or high electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518930542765,"sku":"51309241-175","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-tk-ppd011-51309241-175-battery-extension-module-e5q25f5bfpu.jpg?v=1766982087","url":"https:\/\/www.maxwellplc.com\/products\/51309241-175-honeywell-tk-ppd011-experion-ls-battery-extension-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}