{"product_id":"51309223-125-honeywell-mu-tamt03-analog-input-multiplexer-module","title":"51309223-125 Honeywell MU-TAMT03 Analog Input Multiplexer Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Honeywell MU-TAMT03,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eidentified by engineering part number 51309223-125,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized signal arbitration module designed to optimize I\/O density within legacy and modern Honeywell DCS architectures.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFunctioning as a high-precision Analog Input Multiplexer,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis unit allows a singular data acquisition channel to sequentially sample multiple field signals.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is particularly effective for large-scale monitoring of non-critical variables where high-speed simultaneous sampling is not required,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ebut cost-effective port utilization is essential.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy consolidating disparate inputs—such as secondary temperature points or pressure transmitters—into a streamlined processing path,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe MU-TAMT03 significantly reduces the physical hardware footprint and cabling complexity of the control system.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eHardware Specifications and Signal Processing Attributes\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe MU-TAMT03 is engineered for maximum signal fidelity,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that the switching process does not introduce impedance-related errors or signal degradation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Category\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Signal Multiplexer \/ Router\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Lineage\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell MU-T Series \/ TDC 3000 \/ Experion PKS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Capability\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMulti-channel sequential signal routing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSwitching Logic\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eLow-noise,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ehigh-speed solid-state or relay-based switching for minimal crosstalk\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBroad compatibility with 4-20mA loops and low-voltage analog transmitters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDiagnostic Transparency\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated health monitoring to ensure switching timing and channel integrity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConstruction\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial-grade PCB with enhanced shielding against electromagnetic interference (EMI)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChassis Footprint\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e12.\u003c\/span\u003e\u003cspan class=\"\"\u003e1 x 5 x 30.\u003c\/span\u003e\u003cspan class=\"\"\u003e8 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eUnit Weight\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e76 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInternational Trade Code\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHS 8537101190\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Deployment and Site Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis multiplexing module is a foundational component for data-heavy industrial environments that prioritize efficient infrastructure management.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLarge-Scale Thermal Mapping\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eConsolidating signals from dozens of RTDs or thermocouples across extensive boiler walls or distillation columns for centralized temperature profiling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSCADA and Remote Telemetry\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eExpanding the capacity of remote terminal units (RTUs) in water treatment or pipeline monitoring where physical expansion slots are limited.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Trend Analysis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRouting secondary sensor data to data historians for long-term predictive maintenance and efficiency modeling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTank Farm Monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSequentially polling level and pressure sensors across multiple storage vessels to provide a comprehensive overview of site inventory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Lifecycle Extension\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProviding a reliable, brand-new replacement for legacy MU-T series hardware to maintain the functionality of established DCS racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518926839981,"sku":"51309223-125","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-mu-tamt03-51309223-125-analog-input-multiplexer-vpi2ucoegyu.jpg?v=1766981964","url":"https:\/\/www.maxwellplc.com\/products\/51309223-125-honeywell-mu-tamt03-analog-input-multiplexer-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}