{"product_id":"51308388-175-honeywell-cc-tdil11-digital-input-termination-assembly","title":"51308388-175 Honeywell CC-TDIL11 Digital Input Termination Assembly","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Honeywell CC-TDIL11,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epart number 51308388-175,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eis a robust 24V DC Digital Input Termination Assembly (IOTA) engineered for the Experion PKS Series C ecosystem.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module acts as the specialized physical mounting base and electrical interface for Series C Digital Input modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIt is specifically designed to manage high-density field wiring,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding a streamlined path for discrete signals to reach the control logic.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy consolidating 24V DC field connections into a structured termination point,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe CC-TDIL11 ensures signal clarity and simplifies the deployment of safety-instrumented systems and general process control loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003ePerformance Benchmarks and Hardware Properties\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 51308388-175 IOTA is constructed with industrial-grade materials to maintain electrical integrity in environments prone to vibration and thermal fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLogic Voltage:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e24V DC Optimized\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for Series C Digital Input (DI) Modules\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTermination Density:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports high-density field wiring via standardized terminal blocks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Architecture:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eNative integration with Experion PKS and Honeywell Safety Manager\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eConnectivity:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHigh-integrity gold-plated interface pins for reliable module-to-base communication\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInstallation:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e12-inch IOTA format for vertical carrier mounting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Mass:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e46 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExterior Dimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e29.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 x 12 x 6.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCountry of Origin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eClassification:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eHS Code 8537101190\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eCritical Field Deployment Scenarios\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis Digital Input IOTA is a foundational component for industrial infrastructures where discrete signal accuracy is essential for operational uptime.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Interlock Aggregation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eServing as the termination point for emergency stop buttons and safety gate sensors in chemical processing plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotor Control Status Loops:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRouting \"Run,\" \"Stop,\" and \"Trip\" feedback signals from large industrial motor starters to the central DCS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eValve Limit Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterfacing with discrete position switches on automated piping manifolds to confirm successful valve travel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Distribution Feedback:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapturing auxiliary contact states from circuit breakers in high-voltage switchgear for real-time electrical monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDCS Modernization:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProviding a scalable termination platform for expanding discrete monitoring capabilities in existing Honeywell Series C control cabinets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518930116781,"sku":"51308388-175","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-cc-tdil11-51308388-175-digital-input-iota-24v-model-mkcnisk305x.jpg?v=1766982080","url":"https:\/\/www.maxwellplc.com\/products\/51308388-175-honeywell-cc-tdil11-digital-input-termination-assembly","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}