{"product_id":"51306977-175-honeywell-8u-taix61-analog-input-i-o-module","title":"51306977-175 Honeywell 8U-TAIX61 Analog Input I\/O Module","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Honeywell 8U-TAIX61 (Part number 51306977-175) is a high-precision Analog Input interface engineered for the Experion PKS Series 8 I\/O architecture.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is a cornerstone for high-fidelity data acquisition,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003econverting low-level field signals into digitized process variables for the C300 controller.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for dense industrial environments,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 8U-TAIX61 provides 16 differential analog input channels,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring superior noise rejection and signal isolation.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts primary role is to maintain the integrity of critical measurements such as pressure,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etemperature,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand flow,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding the foundational data required for advanced process control and plant-wide safety monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eCritical Hardware Metrics \u0026amp; Performance Data\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 8U-TAIX61 is characterized by the following technical specifications and environmental ratings:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Identification:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e8U-TAIX61\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eEngineering Number:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e51306977-175\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eInput Configuration:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e16-Channel Differential Analog Input\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePrecision Accuracy:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e±0.\u003c\/span\u003e\u003cspan class=\"\"\u003e05% of full scale for high-resolution sensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCommunication Protocol:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports integration with Modbus RTU for expanded diagnostics\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProduct Series:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSeries 8 I\/O\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Dimensions:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e29.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 x 12 x 7 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eUnit Weight:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e0.\u003c\/span\u003e\u003cspan class=\"\"\u003e34 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Compatibility:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eStandard 4-20mA current loops and voltage inputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOrigin:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eThermal Tolerance:\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt for extended temperature ranges in cabinet-mounted industrial settings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Performance Contexts\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eIn\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eOil, Gas, and Petrochemical Refining\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 8U-TAIX61 is deployed to monitor complex reactor variables.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe module's differential input design is essential in these environments to filter out the electromagnetic interference generated by heavy machinery,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring that the DCS receives a clean,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eaccurate representation of field pressures and temperatures to prevent process excursions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eWithin\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003eChemical Manufacturing and Batch Processing\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis analog input module manages the interface for high-precision level and mass-flow transmitters.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts exceptional accuracy of ±0.\u003c\/span\u003e\u003cspan class=\"\"\u003e05% ensures that chemical ratios are maintained within strict tolerances,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003edirectly influencing product yield and consistency.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe Series 8 architecture also supports hot-swappable maintenance,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing for module replacement without interrupting active control loops.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eFor\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e\u003cstrong class=\"\"\u003ePower Generation and Utility Management\u003c\/strong\u003e\u003cspan class=\"\"\u003e,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 51306977-175 provides a reliable gateway for steam cycle monitoring and environmental emissions tracking.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe robust construction allows it to operate in high-vibration and thermally fluctuating zones near turbine halls.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy integrating via standard industrial protocols,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit facilitates a decentralized control philosophy,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eenabling the aggregation of multiple sensor inputs into a streamlined data stream for real-time analysis and historical logging.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":45518923169965,"sku":"8U-TAIX61","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/honeywell-8c-taix61-8u-taix61-51306977-175-analog-input-module-isyfu4vexzb.jpg?v=1766981837","url":"https:\/\/www.maxwellplc.com\/products\/51306977-175-honeywell-8u-taix61-analog-input-i-o-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}