{"product_id":"5069-l3100erm-allen-bradley-motion-controller-compactlogix-5380","title":"5069-L3100ERM Allen-Bradley Motion Controller CompactLogix 5380","description":"\u003cp\u003eThe \u003cb\u003eAllen-Bradley 5069-L3100ERM\u003c\/b\u003e, also cataloged as the \u003cb\u003e5069-L3100\u003c\/b\u003e Motion Controller, operates as a dedicated hardware component for deterministic axis synchronization and high-speed logic execution within EtherNet\/IP Ethernet network architectures.\u003c\/p\u003e\n\u003ch3\u003eFunctional Suffix Architecture\u003c\/h3\u003e\n\u003cp\u003eThe model number \u003cb\u003e5069-L3100ERM\u003c\/b\u003e uses functional suffix designations. The base platform \u003cb\u003e5069-L3100\u003c\/b\u003e identifies the central processing unit, while the suffix flags specific functional hardware features. The letter \"E\" designates dual embedded Ethernet ports, \"R\" signifies support for Device Level Ring (DLR) network fault tolerance, and \"M\" denotes Integrated Motion over EtherNet\/IP capability.\u003c\/p\u003e\n\u003ch3\u003eHardware Performance Data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5069-L3100ERM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.84 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e144 x 137 x 98 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8.5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUser Memory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 MB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLocal I\/O Expansion Limit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31 modules\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x RJ45 EtherNet\/IP, 1 x USB 2.0 Client\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBus Current Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e450 mA at 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Ethernet Network Execution \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb\u003eAllen-Bradley 5069-L3100ERM\u003c\/b\u003e features high-velocity backplane bus communication across local Compact I\/O modules while maintaining EtherNet\/IP deterministic network timing. Dual Ethernet interfaces enable linear, star, or fault-tolerant DLR topology layouts without external switches. Operating firmware flash compatibility ensures real-time synchronization between motion routines, standard ladder logic execution, and field drive hardware.\u003c\/p\u003e\n\u003ch3\u003eIncluded Package Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 5069-L3100ERM Controller Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 5069-RTB64-SCREW Removable Terminal Block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 5069-ECR End Cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDIN-Rail Mounting\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMount unit vertically onto standard 35 mm zinc-plated steel DIN rail. Ensure rear mounting latch clicks firmly to establish solid chassis ground continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShield Termination\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eConnect Ethernet communication cable shields directly to the main enclosure grounding bus bar using standard low-impedance ground straps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Wiring\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eStrip copper wiring conductors to 10 mm. Tighten terminal block screws to a torque rating of 0.5 to 0.6 Nm to prevent high-resistance connection points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Engineering FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the hot-swap restriction for this controller?\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe main controller module does not support removal or insertion under power (RIUP). Operating power must be isolated from the backplane before removing the unit to avoid system hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow much backplane current does the processor draw from the 5 VDC rail?\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe unit draws up to 450 mA from the internal 5 VDC MOD power bus during normal processing operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat latency impact occurs during network failover on a DLR ring?\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe internal network switch recovers ring communication within 3 ms following a single physical cable disconnection event.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes firmware flash upgrading require removing the local I\/O modules?\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eNo, firmware updates transmit over the front USB port or Ethernet interfaces without disconnecting adjacent local 5069 I\/O hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ground conductor gauge is recommended for the main enclosure earth connection?\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eUse stranded copper wire with a cross-sectional area of at least 2.5 mm sq (14 AWG) connected directly to the central earth ground point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the system respond to an open circuit on the terminal block assembly?\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAn open connection triggers a module loss-of-signal fault, halting local execution and driving assigned digital output channels to safe states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs a lithium battery required for application memory retention during power isolation?\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eNo, internal non-volatile memory stores user programming and system parameters permanently without relying on battery power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable clearance distance is mandatory for front panel wiring management?\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a minimum clearance of 50 mm in front of the terminal connectors to prevent mechanical stress on cable strain reliefs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47230571511981,"sku":"5069-L3100ERM","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley_5069-l3100erm_1.jpg?v=1786893754","url":"https:\/\/www.maxwellplc.com\/products\/5069-l3100erm-allen-bradley-motion-controller-compactlogix-5380","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}