{"product_id":"440r-gl2s2p-allen-bradley-guard-locking-proximity-inputs-safety-relay","title":"440R-GL2S2P Allen-Bradley Guard Locking Proximity Inputs Safety Relay","description":"\u003cp\u003eConfigured for safety-rated guard locking and proximity sensor signal processing in industrial automation systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 440R-GL2S2P\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e440R-GL2S2P\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSafety Relay) provides direct physical and electrical execution of machine interlocking logic.\u003c\/p\u003e\n\u003ch3\u003eCatalog Designation and Operational Logic\u003c\/h3\u003e\n\u003cp\u003eThe 440R-GL2S2P module operates as a dedicated interface between field-level proximity sensors and the machine safety control loop. The \"GL\" designation identifies the hardware's function in managing guard locking mechanisms, while the \"2S2P\" suffix defines the specific input\/output configuration tailored for high-integrity interlocking applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e440R-GL2S2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9.2 x 5 x 7.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConsult Documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.8 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (-15% to +10%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 NO\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAuxiliary Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 NC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Industrial Control Integration\u003c\/h3\u003e\n\u003cp\u003eThe 440R-GL2S2P supports integration into deterministic control architectures, ensuring that status transitions are registered within defined time intervals. It maintains I\/O density scaling capabilities compatible with PLC and distributed control environments. The hardware logic supports Profinet\/EtherNet\/IP deterministic network integration when interfaced through appropriate gateway modules, ensuring that state information is reported to the controller with minimal latency. Firmware compatibility is fixed to ensure consistent logic execution across safety-rated applications.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 440R-GL2S2P Safety Relay module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical terminal configuration sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Install the relay on a standard 35 mm DIN rail. Ensure the vertical orientation is maintained to facilitate natural convection cooling of internal components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Terminate the safety common to the protective earth (PE) bus. Maintain strict segregation between high-voltage power lines and low-voltage safety input signals to prevent inductive interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Use shielded twisted-pair cables for proximity sensor inputs. Limit total cable length to values specified for the connected sensor type to prevent signal attenuation and voltage drop issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eNo. The module must be isolated from the power supply before any physical removal or installation to prevent damage to the relay terminals or the backplane connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response time of the safety outputs?\u003c\/p\u003e\n\u003cp\u003eThe response time is determined by the input signal processing duration and the mechanical switching time of the internal relay contacts. Refer to the manual for specific millisecond ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the NC auxiliary output be used for safety functions?\u003c\/p\u003e\n\u003cp\u003eNo. The NC auxiliary output is provided for diagnostic status reporting only and must not be utilized for safety-rated machine stop or interlock operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should I address a power fluctuation?\u003c\/p\u003e\n\u003cp\u003eIf the input voltage drops below the 24 V DC (-15%) threshold, the relay may transition to a non-safe state or experience output chatter. Ensure the power supply is regulated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the firmware user-accessible?\u003c\/p\u003e\n\u003cp\u003eNo. The firmware is locked to ensure compliance with functional safety standards. No user-configurable software or field-upgradeable parameters exist for this model.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre the input channels redundant?\u003c\/p\u003e\n\u003cp\u003eYes. The relay is designed for dual-channel input configurations, allowing the detection of short-circuit faults between channels to ensure the integrity of the safety signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of current consumption fluctuations?\u003c\/p\u003e\n\u003cp\u003eThe relay draws approximately 200 mA during nominal operation. Ensure the 24 V DC supply is sized correctly to handle the combined load of the relay and connected sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of proximity sensors are compatible?\u003c\/p\u003e\n\u003cp\u003eThe module is designed for compatibility with standard 24 V DC sourcing proximity sensors that provide consistent input signal levels for dual-channel safety monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066474156205,"sku":"440R-GL2S2P","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen_bradley_440r-gl2s2p_1.jpg?v=1783849784","url":"https:\/\/www.maxwellplc.com\/products\/440r-gl2s2p-allen-bradley-guard-locking-proximity-inputs-safety-relay","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}