{"product_id":"4201n-triconex-remote-extender-module-tricon-systems","title":"4201N Triconex Remote Extender Module Tricon Systems","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Triconex 4201N is a high-integrity Remote Extender Module designed to bridge the physical gap between a central Tricon controller and geographically distributed I\/O chassis.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFunctioning as a critical link in Triple Modular Redundant (TMR) safety systems,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 4201N enables the expansion of safety instrumented functions (SIF) across large-scale industrial sites without signal degradation.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy utilizing high-speed communication links,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit allows remote I\/O racks to operate with the same deterministic performance and safety integrity as those located in the local cabinet.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis module is essential for facilities that require a centralized logic solver to manage field devices located in distant process areas,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eensuring a unified safety perimeter.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003ePerformance Architecture and Hardware Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Function\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRemote Chassis Extension and Signal Bridging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Lineage\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eTricon V9 \/ V10 Systems (Tricon Systems)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundancy Level\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports Triple Modular Redundant (TMR) link paths\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eTransmission Media\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports high-bandwidth fiber optic or copper cabling for EMI immunity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDiagnostic Coverage\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated hardware error-checking and link status monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eScalability\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eAllows for multiple remote clusters connected to a single main controller\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Weight\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1.\u003c\/span\u003e\u003cspan class=\"\"\u003e88 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChassis Dimensions\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 cm x 40.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm x 40.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOperating Range\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial grade for hazardous and high-interference zones\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eProduction Status\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eActive\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eStrategic Deployment and Field Utility\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 4201N module is strategically utilized in environments where centralized control and decentralized field sensing are required:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eExpansive Petrochemical Refineries\u003c\/strong\u003e\u003cspan class=\"\"\u003eConnecting I\/O racks located at distant tank farms or loading docks to the main control room logic solver,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ereducing the need for multiple independent safety systems and streamlining maintenance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eOffshore Oil and Gas Platforms\u003c\/strong\u003e\u003cspan class=\"\"\u003eManaging signal transmission between various decks and modules on a platform where space is limited,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ebut safety-critical devices must be monitored across the entire structure with millisecond precision.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMining and Ore Processing\u003c\/strong\u003e\u003cspan class=\"\"\u003eFacilitating safety oversight for remote conveyor systems and crushing stations.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe 4201N's support for fiber optics ensures that long-distance runs remain unaffected by the high electrical noise generated by heavy machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLarge-Scale Power Generation\u003c\/strong\u003e\u003cspan class=\"\"\u003eDistributing I\/O points across boiler and turbine zones while maintaining a centralized \"Single Point of Truth\" for safety logic,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ewhich simplifies the execution of emergency shutdown (ESD) sequences.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Expansion and Retrofitting\u003c\/strong\u003e\u003cspan class=\"\"\u003eAllowing existing facilities to add new process loops and I\/O capacity in remote locations without requiring a complete redesign of the core Triconex safety architecture.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":45519063449773,"sku":"4201N","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/triconex-4201n-remote-extender-module-lrnpvoxj5ht.jpg?v=1766986016","url":"https:\/\/www.maxwellplc.com\/products\/4201n-triconex-remote-extender-module-tricon-systems","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}