{"product_id":"4200n-triconex-remote-extender-module-rxm-safety-system","title":"4200N Triconex Remote Extender Module RXM Safety System","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Triconex 4200N is a specialized Remote Extender Module (RXM) designed to transcend the physical limitations of a standard localized chassis.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIn complex safety instrumented systems (SIS),\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 4200N serves as the high-speed bridge between the primary Tricon™ controller and remote I\/O expansion racks located at significant distances.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy extending the system’s TriBus backplane,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis module ensures that remote process signals are integrated with the same Triple Modular Redundant (TMR) integrity as those in the main rack.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis capability is essential for large-scale industrial sites where field instrumentation is distributed across vast operational footprints,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003erequiring a fault-tolerant communication link that maintains SIL 3 safety standards regardless of distance.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eInfrastructure Capabilities and Hardware Profiles\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModule Type\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eRemote Extender Module (RXM)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eModel Number\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e4200N\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eDistance Extension\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFacilitates long-range I\/O bus expansion over multi-mode or single-mode fiber optics\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eRedundancy Pathing\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDual-channel fiber optic ports to ensure communication continuity if one cable is damaged\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSignal Integrity\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUtilizes high-immunity optical transmission to eliminate EMI\/RFI interference over long runs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNetwork Compatibility\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSeamlessly integrates with Tricon v9 through v11 system architectures\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eLatency Management\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for deterministic data exchange with minimal jitter for safety-critical logic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Weight\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e1.\u003c\/span\u003e\u003cspan class=\"\"\u003e88 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChassis Footprint\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e2.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 cm x 40.\u003c\/span\u003e\u003cspan class=\"\"\u003e5 cm x 40.\u003c\/span\u003e\u003cspan class=\"\"\u003e0 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Requirement\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eOccupies specialized RXM slots within the Tricon main and expansion chassis\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSafety Rating\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFully compliant with TMR fault-tolerant operational standards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Deployment and Remote Networking\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe 4200N module is the primary choice for infrastructure requiring decentralized safety control:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eVast Petrochemical Complexes\u003c\/strong\u003e\u003cspan class=\"\"\u003eLinking remote tank farm monitoring stations to the central emergency shutdown (ESD) system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe 4200N allows for localized I\/O racks to communicate with the central logic solver without the signal degradation associated with traditional copper cabling.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eUtility-Scale Power Generation\u003c\/strong\u003e\u003cspan class=\"\"\u003eExtending safety oversight to remote water treatment plants or coal handling facilities located kilometers away from the main control room.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe fiber optic interface provides electrical isolation from ground loop potentials between distant buildings.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eUpstream Oil and Gas Production\u003c\/strong\u003e\u003cspan class=\"\"\u003eConnecting decentralized wellhead control panels to a central offshore platform or gathering center.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts ruggedized design and redundant link capabilities ensure that safety logic is never compromised by the harsh environmental stressors of remote sites.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMining and Mineral Refining\u003c\/strong\u003e\u003cspan class=\"\"\u003eManaging safety interlocks across expansive conveyor networks and processing units.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe 4200N enables the safety system to scale dynamically as the facility expands,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eadding remote chassis as new processing veins are opened.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePipeline Pumping and Compression Stations\u003c\/strong\u003e\u003cspan class=\"\"\u003eDistributing safety logic across large pumping stations where the distance between sensors and the central control unit requires a high-bandwidth,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003enoise-immune extension module.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":45519058370733,"sku":"4200N","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/triconex-4200n-remote-extender-module-oalyq3eqmfs.jpg?v=1766985874","url":"https:\/\/www.maxwellplc.com\/products\/4200n-triconex-remote-extender-module-rxm-safety-system","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}