{"product_id":"3kde175513l9100-analog-input-module-ai910n-abb-s900-i-o","title":"3KDE175513L9100 Analog Input Module AI910N ABB S900 I\/O","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"citation-391 citation-end-391\"\u003eThe ABB AI910N, cataloged under order reference 3KDE175513L9100, is a high-density analog input module designed for the S900 remote I\/O system.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eThis component serves as a critical interface for the S900 system, which is widely recognized for its ability to operate within hazardous areas (Zone 1 or Zone 2) when installed in suitable enclosures. The AI910N provides the necessary circuitry to convert signals from field-level sensors into digital data for the host Distributed Control System (DCS). Engineered for longevity and precision, this module facilitates the seamless acquisition of process variables such as temperature, pressure, and level, ensuring that industrial automation systems remain synchronized with real-time field conditions.\u003c\/p\u003e\n\u003ch3\u003eHardware Infrastructure and Operational Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Function\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Input Data Acquisition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Identifier\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAI910N\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Reference\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3KDE175513L9100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan class=\"citation-390\"\u003e\u003c\/span\u003e\u003cstrong\u003eSystem Family\u003c\/strong\u003e\u003cspan class=\"citation-390 citation-end-390\"\u003e\u003cspan\u003e \u003c\/span\u003eS900 I\/O \/ Remote I\/O\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Support\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegration via PROFIBUS DP or Industrial Ethernet (via CI930\/CI940)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMultichannel analog signal processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApproximately 25W peak during full-load operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Climate\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCertified for stability between -25°C and +55°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e2cm x 10.5cm x 11cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSweden\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance Standards\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCE, UL, and ISO 9001 certified\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Deployment and Site Applications\u003c\/h3\u003e\n\u003cp\u003eThe AI910N 3KDE175513L9100 is predominantly utilized in process-heavy sectors such as oil and gas refining, chemical manufacturing, and pharmaceutical production. In these environments, the module is typically mounted on an S900 terminal unit, providing the DCS with high-fidelity telemetry from intrinsic safety (IS) barriers. Its ultra-lightweight 0.1 kg frame allows for dense rack configurations, maximizing cabinet space in remote instrument enclosures. By utilizing standardized communication protocols, the AI910N integrates effortlessly into existing Ethernet router-based diagnostic networks, allowing maintenance teams to verify signal integrity remotely. This ensures that critical automated safety systems and PID control loops maintain the highest possible accuracy, even when operating in unconditioned or electrically noisy field environments.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the AI910N module be replaced while the system is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-389 citation-end-389\"\u003eA: Yes, the S900 I\/O series, including the AI910N, is designed for \"hot-swap\" capability, allowing for module extraction and replacement during active operation without interrupting the data flow of other modules on the same station.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the benefit of the intrinsic safety (IS) design for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The S900 architecture is optimized for hazardous areas. When used within the correct backplane and enclosure, the AI910N facilitates the connection of field devices located in explosive atmospheres without the need for additional external barriers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the AI910N support HART communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"citation-388 citation-end-388\"\u003eA: Many S900 modules, such as the AI930 series, specifically support HART.\u003csup class=\"superscript\"\u003e\u003c\/sup\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eYou should verify the specific revision of the AI910N 3KDE175513L9100 to ensure it meets your requirements for pass-through smart instrument diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do the diagnostic LEDs assist in troubleshooting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module features front-panel status indicators that signal power health and signal faults. This allows technicians to instantly identify if a sensor loop is open or if the module has encountered an internal communication error.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is a specific terminal block required for this 0.1 kg module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The AI910N must be inserted into a compatible S900 terminal unit (TU series). The terminal unit provides the physical wiring connections and determines the internal bus addressing for the module.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45518961803437,"sku":"3KDE175513L9100","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-ai910n-3kde175513l9100-analog-input-module-o5oj2tco1tm.jpg?v=1766983129","url":"https:\/\/www.maxwellplc.com\/products\/3kde175513l9100-analog-input-module-ai910n-abb-s900-i-o","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}