{"product_id":"3g3mx2-a4075-zv1-omron-multi-function-compact-inverter-mx2-series","title":"3G3MX2-A4075-ZV1 Omron Multi-Function Compact Inverter MX2 Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3MX2-A4075-ZV1\u003c\/strong\u003e serves as the primary \u003cstrong\u003e3G3MX2\u003c\/strong\u003e Multi-Function Compact Inverter utilized to execute precise 3-phase 400 V AC motor velocity and torque control across automated motion control platforms.\u003c\/p\u003e\n\u003ch3\u003eVariant Decoder \u0026amp; Ordering Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: Base designation for the MX2 Series compact inverter generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting enclosure framework (rated IP10 minimum) or closed wall-mount design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase 400 VAC supply class rating (380 V to 480 V operating range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e075\u003c\/strong\u003e: Maximum applicable motor capacity of 7.5 kW under continuous heavy-duty load conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Designated application-specific firmware option and specialized regional hardware variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational Parameters \u0026amp; Mechanical Characteristics\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4075-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e26.0 cm x 14.0 cm x 15.5 cm (Shipping Weight: 6.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.5 kW rated motor output capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Line Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP10 minimum enclosure rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFieldbus Synchronization \u0026amp; Internal Microcode Execution\u003c\/h3\u003e\n\u003cp\u003eThe internal architecture leverages backplane bus communication velocity licences to guarantee zero-lag axis coordination across Profinet and EtherNet\/IP deterministic networks. High-density I\/O handling facilitates rapid pulse sequence decoding up to 32 kHz. In-field firmware flash compatibility allows seamless parameter set transfers and driver synchronization without host control interruption.\u003c\/p\u003e\n\u003ch3\u003eStandard Box Shipment\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4075-ZV1 Drive Main Unit\u003c\/li\u003e\n\u003cli\u003e1 x Terminal Shield Assembly Plate\u003c\/li\u003e\n\u003cli\u003e1 x Operator Quick Start Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Cabinet Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Clearance Requirements\u003c\/p\u003e\n\u003cp\u003eMount vertically on a flat heat-dissipating panel, maintaining 100 mm top and bottom clearance to facilitate forced-air thermal convection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding \u0026amp; Cable Isolation\u003c\/p\u003e\n\u003cp\u003eEnclose motor power leads (U, V, W) in continuous 360-degree shielded conduit separate from control signaling wires by 100 mm minimum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround Terminal Termination\u003c\/p\u003e\n\u003cp\u003eBond the protective earth terminal directly to the main cabinet ground bus using high-gauge stranded copper cable to avoid ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDrive Operations Technical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan main line terminals be disconnected while the inverter remains energized under load?\u003c\/p\u003e\n\u003cp\u003eNo. Input mains power must be isolated and DC bus capacitor voltage verified below 50 VDC prior to handling power block terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat hardware response time is guaranteed upon triggering emergency stop safety terminals?\u003c\/p\u003e\n\u003cp\u003eDual safety inputs execute hardware gate shutdown within 10 milliseconds, instantly stripping output torque according to ISO 13849-1 Cat 3 PLd.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the RS485 communication transceiver withstand field noise transients?\u003c\/p\u003e\n\u003cp\u003eThe onboard serial interface uses internal galvanic isolation to eliminate common-mode noise and suppress differential line voltage transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the inverter capable of operating high-speed AC motors above nominal 60 Hz limits?\u003c\/p\u003e\n\u003cp\u003eYes. Configured internal parameters support output speeds up to 1000 Hz, provided motor insulation and mechanical bearing ratings permit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen is an external dynamic braking resistor mandatory for deceleration cycles?\u003c\/p\u003e\n\u003cp\u003eAn external resistor block is required when high-inertia load regenerative energy exceeds the thermal dissipation threshold of the built-in braking chopper.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does ambient temperature derating affect continuous output current capacity?\u003c\/p\u003e\n\u003cp\u003eContinuous output current ratings must be reduced by 2.5% per deg C for ambient enclosure temperatures rising above 40 deg C up to 50 deg C maximum.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an auxiliary battery supply required to preserve parameter settings during blackout conditions?\u003c\/p\u003e\n\u003cp\u003eNo. User parameter files, custom logic sequences, and historical fault data are permanently recorded into non-volatile internal EEPROM storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal shielding method prevents analog reference drift on 4-20 mA control loops?\u003c\/p\u003e\n\u003cp\u003eTerminate the cable braid shield to the drive earth point only on the inverter side to eliminate differential ground potential currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306623123629,"sku":"3G3MX2-A4075-ZV1","price":142.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3mx2-a4075-zv1_1.jpg?v=1787722912","url":"https:\/\/www.maxwellplc.com\/products\/3g3mx2-a4075-zv1-omron-multi-function-compact-inverter-mx2-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}