{"product_id":"3g3mx2-a4015-zv1-omron-frequency-inverter-mx2-series","title":"3G3MX2-A4015-ZV1 Omron Frequency Inverter MX2 Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3MX2-A4015-ZV1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3G3MX2-A4015\u003c\/strong\u003e Frequency Inverter, operates as a dedicated hardware component for open-loop motor speed regulation and torque control within industrial drive network architectures.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: MX2 Series compact inverter platform designation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA4\u003c\/strong\u003e: 3-phase 380 to 480 VAC input voltage class.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e015\u003c\/strong\u003e: 1.5 kW max applicable motor capacity rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Integrated internal software and parameter functionality revision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Performance Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4015-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e3.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 kW (Rated motor output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 to 480 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 to 480 VAC (Cannot exceed input voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBraking Resistor Duty Cycle\u003c\/td\u003e\n\u003ctd\u003eBRD usage is 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarmonic Suppression Option\u003c\/td\u003e\n\u003ctd\u003e3G3AX-NFI23 (CT rating supported only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Methods\u003c\/td\u003e\n\u003ctd\u003eOpen loop torque control, PID control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Fieldbus Integration \u0026amp; Motor Drive Dynamics\u003c\/h3\u003e\n\u003cp\u003eHigh starting torque and vector control capabilities in open loop mode deliver precise machine dynamics and motion profiles. The drive supports open network fieldbus communication options, enabling real-time status exchange and setpoint transfer over EtherNet\/IP deterministic networks. Backplane bus communication velocity across optional option cards ensures low-latency register access, while firmware flash compatibility guarantees predictable motor speed response during multi-axis synchronization.\u003c\/p\u003e\n\u003ch3\u003eStandard Package Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4015-ZV1 Frequency Inverter\u003c\/li\u003e\n\u003cli\u003e1 x Front Control Keypad Interface\u003c\/li\u003e\n\u003cli\u003e1 x Cable Grounding Plate Kit\u003c\/li\u003e\n\u003cli\u003e1 x Quick Start Instruction Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Clearance\u003c\/strong\u003e: Mount the unit vertically on a flat panel inside an IP54 or higher control cabinet, maintaining a minimum 100 mm top and bottom clearance for thermal dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Line Reactor Wiring\u003c\/strong\u003e: Connect an optional AC reactor to the main supply lines to suppress harmonic current generated from the inverter, especially if power supply capacity exceeds drive capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Choke Configuration\u003c\/strong\u003e: Install a DC reactor across the internal DC link terminals for improved harmonic mitigation compared to standard AC line reactors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor \u0026amp; Line Grounding\u003c\/strong\u003e: Route input power cables (3-phase 380 to 480 VAC) and motor power leads in separate grounded metallic conduits to avoid high-frequency noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat limits exist on the maximum output voltage supplied to the AC motor?\u003c\/p\u003e\n\u003cp\u003eThe output voltage ranges up to 3-phase 380 to 480 VAC and cannot exceed the incoming line voltage under any operational state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat constraint applies when using the 3G3AX-NFI23 filter option with this drive?\u003c\/p\u003e\n\u003cp\u003eWhen configured with the 3G3AX-NFI23 noise filter option, only the Heavy Duty (CT) rating specification is supported.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum allowable duty cycle for internal dynamic braking?\u003c\/p\u003e\n\u003cp\u003eThe built-in dynamic braking transistor circuit operates with a maximum braking resistor duty cycle (BRD usage) of 10%.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow can harmonic current generation be minimized effectively?\u003c\/p\u003e\n\u003cp\u003eA DC reactor suppresses harmonic current better than an AC reactor, and both components can be installed simultaneously for maximum reduction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen should an AC reactor be connected to the AC power input lines?\u003c\/p\u003e\n\u003cp\u003eConnect an AC reactor if power supply capacity greatly exceeds inverter rating, or if power factor improvement is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the inverter support closed-loop encoder feedback for speed control?\u003c\/p\u003e\n\u003cp\u003eThe drive delivers high starting torque and precise torque regulation strictly in open loop mode without requiring encoder feedback.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat process control features are integrated directly into the firmware?\u003c\/p\u003e\n\u003cp\u003eThe unit features internal PID control, multi-step speed selection, starting frequency adjustment, carrier frequency adjustment, and jogging operation modes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are fieldbus communications integrated into the drive platform?\u003c\/p\u003e\n\u003cp\u003eOptional communication cassettes interface directly with major open network systems, connecting the drive to field controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306649436333,"sku":"3G3MX2-A4015-V1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3g3mx2-a4015-zv1_1_3.jpg?v=1790391946","url":"https:\/\/www.maxwellplc.com\/products\/3g3mx2-a4015-zv1-omron-frequency-inverter-mx2-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}