{"product_id":"3bse020508r1-di801-abb-digital-input-module-s800-i-o-16-channel","title":"3BSE020508R1 DI801 ABB Digital Input Module S800 I\/O 16-Channel","description":"\u003cp\u003eConfigured for high-density digital signal acquisition in ABB Ability System 800xA platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB 3BSE020508R1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eDI801\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input Module) provides direct physical and electrical execution of 24 V DC binary input processing across 16 channels.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix \u0026amp; Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDI801: Base model identifier for 16-channel digital input functionality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e3BSE020508R1: Order reference for standardized manufacturing release.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eI\/O Architecture: Integrated 16-channel binary acquisition with common optical isolation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE020508R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.9 cm x 4.5 cm x 10.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 mA per channel at 24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eI\/O Density\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16-Channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eController Integration \u0026amp; Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe DI801 module functions within the AC 800M controller ecosystem, utilizing the S800 I\/O bus to facilitate deterministic data exchange. Firmware flash compatibility allows for version synchronization with the Control Builder M software environment. High-speed backplane bus communication velocity ensures that state changes are reported to the CPU with minimal latency, supporting real-time logic execution. The module architecture supports I\/O density scaling, allowing for multiple DI801 units to be addressed within a single cluster configuration without bus contention.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 3BSE020508R1 DI801 Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical data sheet documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Procedures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Base Mounting: Seat the module onto a compatible S800 I\/O terminal base (e.g., TU810 or TU814) to establish physical bus connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField Wiring: Terminate 24 V DC binary signals to the corresponding terminal base contact points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Ensure the terminal base is properly bonded to the cabinet ground bus to maintain EMC integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHot-Swap Sequence: Use module locking latches for removal and insertion; verify system configuration before re-initiating the I\/O channel scan.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs the DI801 compatible with AC signals? No, it is strictly designed for 24 V DC signals; AC input will cause permanent optical isolation damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the internal power supply fails? The 16th channel can be configured to supervise the external power group health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module support hot-swapping? Yes, the module supports hot-insertion and removal when mounted on an active S800 terminal base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre the inputs isolated? Yes, the module utilizes optical galvanic isolation between the field inputs and the system logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of the onboard LEDs? The front-panel LED matrix provides status indication for individual input channels and module health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module be used with older controller versions? Yes, firmware and hardware compatibility are maintained within the ABB AC 800M ecosystem.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes it require external signal filtering? No, each channel includes hardware-based EMC noise filtration and debouncing logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are input states processed? The module converts mechanical or sensor states into digital logic readable by the controller backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45518757494957,"sku":"3BSE020508R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-di801-3bse020508r1-digital-input-module-iencnb2zmiz.jpg?v=1782439159","url":"https:\/\/www.maxwellplc.com\/products\/3bse020508r1-di801-abb-digital-input-module-s800-i-o-16-channel","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}