{"product_id":"3bhe036348r0102-abb-xzc826a102-control-circuit-board-advant-ocs","title":"3BHE036348R0102 ABB XZC826A102 Control Circuit Board Advant OCS","description":"\u003cp\u003eConfigured for high-speed signal processing in Advant OCS and 800xA systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB XZC826A102\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3BHE036348R0102\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControl Circuit Board) provides direct physical and electrical execution of analog measurement acquisition and load limiting.\u003c\/p\u003e\n\u003ch3\u003eIdentification Matrix\u003c\/h3\u003e\n\u003cp\u003eThe XZC826A102 model (3BHE036348R0102) is a specialized circuit assembly designed for integration into ABB distributed control system (DCS) cabinets. It serves as a localized interface module for processing real-time inputs with a measurement update cycle of less than 40 ms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eXZC826A102 (3BHE036348R0102)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22.7 cm x 12.9 cm x 1.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard industrial range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 mW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 Veff (EN 50020)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control and Backplane Bus Communication\u003c\/h3\u003e\n\u003cp\u003eThe XZC826A102 operates as an I\/O processing node within the Advant OCS\/800xA ecosystem. The module leverages deterministic backplane bus communication velocity to meet sub-40 ms update requirements. Firmware flash compatibility is managed via the controller's main processing unit, ensuring that the circuit board operates within the current cabinet-level I\/O density scaling parameters. This design allows for seamless integration into existing rack-based architectures while maintaining the strict timing constraints required for process control loops.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eXZC826A102 Control Circuit Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration and technical documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDisconnect power from the I\/O rack prior to board installation or removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInsert the board into the designated slot, ensuring all backplane pins are aligned and fully seated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTighten retaining screws to ensure proper grounding to the rack chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm that the channel-wise electrical isolation matches the loop requirements for connected field sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify input signals at the terminal level after installation to confirm correct mapping within the control configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this board support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: No, power must be disconnected from the backplane segment to prevent electrical arcing or damage to the module pins during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this module compatible with older ABB MasterPiece systems?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility is limited to Advant OCS and 800xA platforms; check system revision compatibility before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the electronic current limiting?\u003c\/p\u003e\n\u003cp\u003eA: It protects the circuit board and downstream electronics from overcurrent events, limiting current to 28.5 mA or less.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the board handle signal interference?\u003c\/p\u003e\n\u003cp\u003eA: It incorporates channel-wise electrical isolation to maintain signal integrity in environments with high electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is firmware on the board field-upgradable?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on the system controller firmware; specific board-level logic is fixed per hardware revision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this for non-analog control signals?\u003c\/p\u003e\n\u003cp\u003eA: The board is optimized for specific measurement inputs; refer to the wiring diagram for valid signal types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the \"Connected Load\" specification?\u003c\/p\u003e\n\u003cp\u003eA: The 600 mW connected load defines the thermal dissipation requirement for cabinet cooling calculations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the board store configuration data?\u003c\/p\u003e\n\u003cp\u003eA: No, the board performs passive signal processing; all logic resides in the central DCS controller or local I\/O processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231196537005,"sku":"3BHB000272R0101","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-ufc719ae01-3bhb000272r0101-ioec-io-interface-bny4puc01ji_f9eeae1b-7002-4e4d-9ed4-b366429b03e5.jpg?v=1762942466","url":"https:\/\/www.maxwellplc.com\/products\/3bhe036348r0102-abb-xzc826a102-control-circuit-board-advant-ocs","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}