{"product_id":"3bhe026955r0633-abb-uns4017a-e-thyristor-packet-advant-ocs-800xa","title":"3BHE026955R0633 ABB UNS4017A-E Thyristor Packet Advant OCS\/800xA","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB 3BHE026955R0633\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUNS4017A-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThyristor Packet, operates as a dedicated hardware component for high-current power switching within Advant OCS and 800xA automation platforms. This semiconductor assembly provides controlled rectification and voltage regulation, executing power modulation through solid-state switching transitions.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe \"UNS4017A-E\" identifier denotes the specific electrical rating and thermal interface configuration for the thyristor assembly. The suffix \"Va\" indicates the internal semiconductor arrangement optimized for Advant OCS and 800xA power converter architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BHE026955R0633 UNS4017A-E\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24.0 x 19.0 x 5.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApplication Dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCore Performance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControlled Rectification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eABB Industrial Control \u0026amp; Drive Communication\u003c\/h3\u003e\n\u003cp\u003eThe UNS4017A-E thyristor packet utilizes standard ABB converter signaling to interface with gate driver units. It maintains high backplane bus communication velocity indirectly through synchronized triggering pulses, ensuring deterministic switching performance. The module is fully firmware flash compatible with the surrounding control assembly, allowing for precise control of load currents without requiring physical adjustments to I\/O density scaling. The solid-state interface provides noise-immune power regulation, critical for the stability of DCS-monitored high-current circuits.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e3BHE026955R0633 UNS4017A-E Va thyristor packet unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical documentation for converter assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eESD-compliant protective packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eClean all contact surfaces of the heat sink to ensure minimal thermal resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply an even layer of thermal conductive paste to the baseplate before mechanical tightening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure mounting hardware to the specified torque rating to ensure uniform pressure across the thyristor die.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that gate trigger leads are connected with correct polarity to avoid firing sequence errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute high-current busbars according to the cabinet layout to maintain clearance distances and prevent arcing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this component field-repairable?\u003c\/p\u003e\n\u003cp\u003eA: No, the thyristor packet is a sealed semiconductor assembly. Any failure of the internal die requires the replacement of the entire packet unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the thyristor triggered?\u003c\/p\u003e\n\u003cp\u003eA: It is triggered by low-voltage pulses provided by the system’s dedicated gate driver module, which manages the precise firing angle for power regulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this unit replace older SCR packets?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is a direct functional replacement for existing UNS4017A series units in ABB converter subsystems, provided the part numbers match.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does it require active cooling?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the thyristor must be mounted on an adequate heat sink to dissipate losses generated during high-current conduction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I verify if the thyristor is operational?\u003c\/p\u003e\n\u003cp\u003eA: Use an ohmmeter to check for open or short circuits across the anode\/cathode, though dynamic testing under full load is the only way to confirm switching performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can multiple packets be connected in series?\u003c\/p\u003e\n\u003cp\u003eA: Yes, they can be configured in series or parallel arrangements within an ABB power assembly to meet specific voltage or current requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this module sensitive to voltage transients?\u003c\/p\u003e\n\u003cp\u003eA: Thyristors have finite voltage ratings; ensure the input circuit is protected by proper snubber networks and voltage suppressors to prevent overvoltage damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the significance of the 800xA compatibility?\u003c\/p\u003e\n\u003cp\u003eA: It signifies that the module meets the electrical and physical footprint standards required for seamless integration into 800xA-managed power converter assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231195816109,"sku":"3BHE026955R0633","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-3bhe026955r0633-uns4017a-e-va-thyristor-packet-nqr2z1l4k1o_c4ae84e4-5ff4-46df-b732-c256c1110546.jpg?v=1762942460","url":"https:\/\/www.maxwellplc.com\/products\/3bhe026955r0633-abb-uns4017a-e-thyristor-packet-advant-ocs-800xa","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}