{"product_id":"3bhb002483r0001-usc329ae01-abb-ac-800pec-control-board","title":"3BHB002483R0001 USC329AE01 ABB AC 800PEC Control Board","description":"\u003cp\u003eThe \u003cb\u003eABB 3BHB002483R0001 USC329AE01\u003c\/b\u003e, also cataloged as the \u003cb\u003eUSC329AE01\u003c\/b\u003e Control Board, operates as a dedicated hardware component for analog and digital signal processing, serial communications, and fieldbus interfacing within \u003cb\u003eAC 800PEC\u003c\/b\u003e drive controller systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Nomenclature and Reference Mapping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e3BHB002483R0001\u003c\/b\u003e: Official ABB manufacturing part number and spare ordering reference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eUSC329AE01\u003c\/b\u003e: Specific control board variant and circuit assembly revision code.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eControl Board\u003c\/b\u003e: Hardware classification responsible for signal acquisition and field communication execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BHB002483R0001 USC329AE01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControl Board\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePlatform\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 800PEC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard backplane circuit load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 channels (0-20 mA, 4-20 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital I\/O Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Interfaces\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRS-485, Ethernet, Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.16 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e38 x 12.7 x 5.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHigh-Speed Backplane Integration \u0026amp; Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe module establishes high-rate data transfer across the AC 800PEC subrack, maintaining high backplane bus communication velocity. Onboard microcontrollers handle deterministic Ethernet and RS-485 communications while preserving I\/O density scaling. Integrated non-volatile flash memory maintains strict firmware flash compatibility across local logic processors and the primary system controller.\u003c\/p\u003e\n\u003ch3\u003eFactory Delivery Package\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB 3BHB002483R0001 USC329AE01 Control Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Anti-static ESD protective bag\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Installation \u0026amp; Field Wiring Protocols\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003ePhysical Card Mounting\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSlide the board firmly into the subrack card slots until the backplane multi-pin connector seats completely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFasten front panel captive screws to a torque limit of 0.6 Nm to ensure solid electrical ground continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eSignal and Bus Cable Installation\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRoute 4-20 mA analog input loops using twisted-pair shielded cables to prevent electromagnetic coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate RS-485 and Modbus bus lines with standard 120 ohm line resistors at both physical cable ends.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a minimum physical distance of 200 mm between low-voltage signal wiring and 400 VAC power circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat analog signal ranges are supported on the board input channels?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe 4 analog input channels natively support standard industrial 0-20 mA and 4-20 mA current signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCan the 3BHB002483R0001 USC329AE01 board be removed while power is applied?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Hot-swapping is not supported; system power must be completely isolated prior to board extraction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eHow is cabinet grounding achieved for this control board assembly?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eChassis grounding is established directly via backplane ground pins and metallic front panel retaining screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat serial and network interfaces are available on the front panel?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit provides RS-485 serial ports, Ethernet network connectors, and integrated Modbus protocol handling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat supply voltage is required to power the board logic circuits?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe module operates from an internal 24 VDC power rail supplied through the rack backplane assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eHow do I prevent communication drops on the RS-485 serial bus?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure proper 120 ohm termination at both ends of the bus and ground the cable shield at one point only.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat ambient thermal limits apply during continuous full-load operation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe operational temperature range is specified from -20 deg C up to +60 deg C in standard industrial enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eHow are firmware version mismatches corrected on replacement boards?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility procedures allow automated synchronization from the primary AC 800PEC processor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021083234477,"sku":"3BHB002483R0001 USC329AE01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_3bhb002483r0001_usc329ae01_2.jpg?v=1787894064","url":"https:\/\/www.maxwellplc.com\/products\/3bhb002483r0001-usc329ae01-abb-ac-800pec-control-board","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}