{"product_id":"3asd573001a5-abb-ypq110a-ulma-i-o-module","title":"3ASD573001A5 ABB YPQ110A ULMA I\/O Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB YPQ110A (order number 3ASD573001A5) is a ULMA I\/O module used in ABB Advant OCS \/ 800xA control environments. It functions as an interface I\/O board for cabinet-level signal handling, supporting deterministic digital signal exchange between field wiring and the control system backplane\/bus.\u003c\/p\u003e\n\u003cp\u003eThis module is typically installed in ABB DCS cabinets where fast digital response and electrical separation are required for reliable operation. It is commonly purchased as a replacement spare for installed systems or as part of life-extension maintenance for existing ABB control architectures.\u003c\/p\u003e\n\u003cp\u003eTechnical correction note\u003cbr\u003eThe field “Ethernet router” is not relevant to this I\/O module. Also, detailed performance claims (such as 1 ms update rate and specific isolation voltages) may be configuration-dependent and cannot be fully verified from the header alone; keep them as typical engineering references and confirm using the ABB hardware manual for YPQ110A \/ ULMA.\u003c\/p\u003e\n\u003ch3\u003eElectrical \u0026amp; Hardware Characteristics\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Order Code\u003c\/td\u003e\n\u003ctd\u003eYPQ110A \/ 3ASD573001A5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eULMA I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Family\u003c\/td\u003e\n\u003ctd\u003eAdvant OCS \/ 800xA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Context\u003c\/td\u003e\n\u003ctd\u003eDCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eBrand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus\u003c\/td\u003e\n\u003ctd\u003eActive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailability\u003c\/td\u003e\n\u003ctd\u003eIn Stock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMOQ\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. Weight\u003c\/td\u003e\n\u003ctd\u003e1.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprox. Dimensions\u003c\/td\u003e\n\u003ctd\u003e4.2 × 22 × 32.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTypical functional characteristics (system dependent)\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e24 VDC powered cabinet module for digital I\/O interfacing (exact I\/O composition depends on ULMA configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed cyclic update behavior suitable for time-sensitive discrete control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for industrial EMI environments with isolation\/segregation practices consistent with ABB DCS cabinet standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEngineering notes\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm the exact I\/O point type and channel count using the site BOM and ABB documentation for ULMA\/YPQ110A variants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFollow site wiring and shielding practices to maintain signal integrity and minimize nuisance trips from induced noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cp\u003eCommon operational scenarios include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete signal acquisition and actuation in process plants using Advant OCS \/ 800xA cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed interlocking and permissive logic where consistent scan\/update behavior is required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation auxiliaries, balance-of-plant systems, and turbine\/package interfaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing and material handling systems where robust cabinet I\/O is required for 24\/7 operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eService considerations\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eApply ESD precautions and cabinet lockout\/tagout procedures during replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAfter installation, verify I\/O diagnostics and perform point checks (input state validation and output forcing tests per site procedure)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure module revision matches the installed rack\/backplane and controller engineering configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45518992081069,"sku":"3ASD573001A5","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-ypq110a-3asd573001a5-ulma-i-o-module-4athkkva4tl.jpg?v=1766984264","url":"https:\/\/www.maxwellplc.com\/products\/3asd573001a5-abb-ypq110a-ulma-i-o-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}