{"product_id":"35ek90-gjr5143100r0001-abb-procontic-t300-bus-coupler-unit","title":"35EK90 GJR5143100R0001 ABB Procontic T300 Bus Coupler Unit","description":"\u003cp\u003eConfigured for deterministic data exchange in Procontic T300 networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB 35EK90 GJR5143100R0001\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e35EK90\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBus Coupler Unit) provides direct electrical synchronization between distributed I\/O stations and localized PLC controllers.\u003c\/p\u003e\n\u003ch3\u003eComponent Identification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e35EK90\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGJR5143100R0001\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Family:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProcontic T300\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35EK90 (GJR5143100R0001)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 x 19.5 x 26.1 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Backplane Power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtocol Support\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFieldbus \/ System-specific\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRack-integrated or DIN-rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Integration\u003c\/h3\u003e\n\u003cp\u003eThe 35EK90 supports backplane bus communication velocity parameters required for maintaining network timing in Procontic T300 architectures. The module facilitates I\/O density scaling by bridging modular segments to the primary system bus. Firmware flash compatibility is managed via the central controller unit to ensure synchronized protocol operation across the automated framework.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 35EK90 Bus Coupler Unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard technical compliance documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated interface connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the module onto the designated carrier or DIN-rail; ensure the 2.0 cm wide housing is properly latched to the backplane connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify the module chassis achieves a low-impedance connection to the cabinet common ground to mitigate electromagnetic interference effects on the bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFollow standard cabling practices for fieldbus segments, ensuring that communication lines are shielded to prevent data corruption during high-frequency switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfirm that the integrated status indicators display healthy communication states before initializing process execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 35EK90 hot-swappable?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, power must be isolated from the backplane segment prior to module insertion or removal to prevent electrical transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require external power?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit typically derives power from the 24 VDC system backplane. Confirm subrack power capacity before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow are communication errors identified?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated status LEDs provide visual feedback on bus health; consult the system diagnostic manual for specific blink codes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this unit be used with non-T300 systems?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo, the 35EK90 is specifically engineered for the Procontic T300 control ecosystem and protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the 2 cm slim profile?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt maximizes point density in high-density control cabinets while minimizing localized thermal accumulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the module configured for the network?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfiguration is managed through the central PLC software; ensure the hardware address is set according to the bus topology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module sensitive to EMI?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe circuitry is hardened for industrial use, but proper cable shielding is required to ensure data integrity in noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it require firmware updates?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFirmware compatibility is version-dependent; refer to the controller system documentation for compatibility matrices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231156166829,"sku":"GJR5143100R0001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-gjr5143100r0001-35ek90-bus-coupler-unit-5rcvjuobeco_a8f3203c-8a2a-4602-8f56-38ae0fb72096.jpg?v=1762942145","url":"https:\/\/www.maxwellplc.com\/products\/35ek90-gjr5143100r0001-abb-procontic-t300-bus-coupler-unit","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}