{"product_id":"3500-22-01-01-r0-bently-nevada-3500-series-transient-data-interface-module","title":"3500\/22-01-01-R0 Bently Nevada 3500 Series Transient Data Interface Module","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/22-01-01-R0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3500\/22M\u003c\/strong\u003e Transient Data Interface Module, operates as a dedicated hardware component for transient waveform acquisition, machinery data communication, and rack-level monitoring within the Bently Nevada 3500 Monitoring System. The module provides USB-B, Ethernet, and transient data processing interfaces for vibration monitoring applications. The 3500\/22M TDI module is specified with 10.5 Watts power consumption and supports BN Host Protocol and BN TDI Protocol communication.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Overview\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/22-01-01-R0 designation identifies the standard Transient Data Interface configuration. The available ordering structure is based on the 3500\/22-AA-BB-CC format, where the TDI type, I\/O module selection, and agency approval option define the hardware configuration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAA: Transient Data Interface Type\n\u003cul\u003e\n\u003cli\u003e01: Standard TDI configuration for standard monitoring applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eBB: I\/O Module Type\n\u003cul\u003e\n\u003cli\u003e01: 10Base-T\/100Base-TX Ethernet\u003c\/li\u003e\n\u003cli\u003e02: 100Base-FX Fiber Optic Ethernet\u003c\/li\u003e\n\u003cli\u003e03: 10Base-T\/100Base-TX Ethernet with gold-plated OK Relay contacts\u003c\/li\u003e\n\u003cli\u003e04: 100Base-FX Fiber Optic Ethernet with gold-plated OK Relay contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCC: Agency Approval\n\u003cul\u003e\n\u003cli\u003e00: None\u003c\/li\u003e\n\u003cli\u003e01: CSA\/NRTL\/C Class 1 Division 2\u003c\/li\u003e\n\u003cli\u003e02: Multi approval including CSA, ATEX, and IECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/22-01-01-R0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003e3500\/22M Transient Data Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (TDI Module), 0.20 kg (I\/O Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm (TDI Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10.5 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Communication Port\u003c\/td\u003e\n\u003ctd\u003eUSB-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e10Base-T \/ 100Base-TX Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Ethernet Option\u003c\/td\u003e\n\u003ctd\u003e100Base-FX Multimode Fiber Optic Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Protocol\u003c\/td\u003e\n\u003ctd\u003eBN Host Protocol and BN TDI Protocol using Ethernet TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Communication\u003c\/td\u003e\n\u003ctd\u003eBN Host Protocol, maximum 115.2 kbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Position\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Position\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyphasor Inputs\u003c\/td\u003e\n\u003ctd\u003eSupports four 3500 system Keyphasor signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Data Channels\u003c\/td\u003e\n\u003ctd\u003eSupports waveform collection for up to 48 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Rating\u003c\/td\u003e\n\u003ctd\u003e5 A @ 24 VDC \/ 120 VAC, maximum 120 Watts \/ 600 VA switched power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eTechnical specifications are based on the 3500\/22M Transient Data Interface datasheet.\u003c\/p\u003e\n\u003ch3\u003eRotor Dynamics and Transient Data Processing\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/22M TDI module processes dynamic machinery signals from the 3500 rack and supports transient recording functions associated with speed variation and alarm events. It collects startup and coastdown data based on programmable speed and time intervals.\u003c\/p\u003e\n\u003cp\u003eThe module supports Keyphasor inputs for speed reference acquisition. Four 3500 system Keyphasor signals can be connected, with supported speed ranges depending on enabled dynamic channels. For 1 to 16 channels, the supported speed range is 1 rpm to 100,000 rpm.\u003c\/p\u003e\n\u003cp\u003eWaveform acquisition supports 48 channels with DC-coupled waveform collection and simultaneous synchronous and asynchronous sampling during operating modes. Configurable synchronous sampling rates include up to 1024 samples per revolution for 2 revolutions.\u003c\/p\u003e\n\u003cp\u003eFor machinery diagnostic analysis, the TDI collects amplitude and phase information from static values, providing four nX static values for each measurement point.\u003c\/p\u003e\n\u003ch3\u003eCommunications and Signal Interface\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/22M provides multiple communication paths for configuration, data acquisition, and diagnostic software connection.\u003c\/p\u003e\n\u003cp\u003eThe front panel USB-B interface supports BN Host Protocol communication with a maximum baud rate of 115.2 kbaud and a maximum cable length of 5 meters.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet interface supports 10Base-T and 100Base-TX communication conforming to IEEE802.3 standards. The module communicates using BN Host Protocol and BN TDI Protocol through Ethernet TCP\/IP.\u003c\/p\u003e\n\u003cp\u003eThe 100Base-FX fiber optic option supports full duplex multimode fiber communication with a maximum cable length of 2000 meters.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/22-01-01-R0 configuration includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 3500\/22M Standard Transient Data Interface Module\u003c\/li\u003e\n\u003cli\u003e1 x 10Base-T\/100Base-TX Ethernet I\/O Module\u003c\/li\u003e\n\u003cli\u003e1 x TDI rear I\/O interface assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional components:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 288055-01 Standard Transient Data Interface Module with USB cable\u003c\/li\u003e\n\u003cli\u003e1 x 146031-01 10Base-T\/100Base-TX I\/O Module\u003c\/li\u003e\n\u003cli\u003e1 x 146031-02 100Base-FX Fiber Optic I\/O Module\u003c\/li\u003e\n\u003cli\u003e1 x 161580 3500\/22M TDI Operation and Maintenance User Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe spare and accessory list is defined in the manufacturer documentation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eRack Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the TDI module in one full-height front slot of the 3500 rack.\u003c\/li\u003e\n\u003cli\u003eInstall the associated I\/O module in one full-height rear slot.\u003c\/li\u003e\n\u003cli\u003eRemove the existing 3500\/20 RIM and RIM I\/O before installing the TDI upgrade.\u003c\/li\u003e\n\u003cli\u003eInsert TDI I\/O first, then insert the TDI module into the rack.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eGrounding and Communication Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect Signal Common to a single-point instrument ground when required.\u003c\/li\u003e\n\u003cli\u003eIsolate Signal Common from chassis ground according to Power Input Module selector settings.\u003c\/li\u003e\n\u003cli\u003eUse shielded Category 5 cable for 10Base-T\/100Base-TX Ethernet connections.\u003c\/li\u003e\n\u003cli\u003eUse MT-RJ female fiber connectors for 100Base-FX fiber connections.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of the 3500\/22M module?\u003c\/p\u003e\n\u003cp\u003eThe module collects transient machinery data, waveform information, and rack communication data from the Bently Nevada 3500 monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the 3500\/22M support Keyphasor signals?\u003c\/p\u003e\n\u003cp\u003eYes. The module supports four 3500 system Keyphasor signals for speed reference and transient data collection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat Ethernet communication types are supported?\u003c\/p\u003e\n\u003cp\u003eThe module supports 10Base-T\/100Base-TX Ethernet and optional 100Base-FX fiber optic Ethernet interfaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat communication protocols are available?\u003c\/p\u003e\n\u003cp\u003eThe module supports BN Host Protocol and BN TDI Protocol through USB and Ethernet TCP\/IP connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many waveform channels can the TDI collect?\u003c\/p\u003e\n\u003cp\u003eThe module supports waveform collection for 48 channels with synchronous and asynchronous sampling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the operating temperature range?\u003c\/p\u003e\n\u003cp\u003eThe operating temperature range is -30 deg C to +65 deg C with 95% non-condensing humidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the 3500\/22M replace a 3500\/20 RIM directly?\u003c\/p\u003e\n\u003cp\u003eNo. The upgrade requires removal of the RIM and RIM I\/O before TDI installation to avoid module damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat grounding requirement applies to USB communication?\u003c\/p\u003e\n\u003cp\u003eThe specified USB cable maintains chassis isolation, and the connected computer should avoid ground connection to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46892239782061,"sku":"3500\/22-01-01-R0","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/350020_25_92a7d851-1c86-4ae4-aac3-65f012478c2d.jpg?v=1784770977","url":"https:\/\/www.maxwellplc.com\/products\/3500-22-01-01-r0-bently-nevada-3500-series-transient-data-interface-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}