{"product_id":"3500-05-01-01-05-00-01-bently-nevada-14-slot-19-inch-rack-chassis","title":"3500\/05-01-01-05-00-01 Bently Nevada 14-Slot 19-inch Rack Chassis","description":"\u003ch3 class=\"\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThe Bently Nevada 3500\/05-01-01-05-00-01 is a full-size,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e19-inch machinery protection chassis designed to provide the core structural and electronic framework for the 3500 Series monitoring system.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBuilt in strict accordance with API 670 requirements,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethis rack serves as the primary interface between field-side vibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eposition,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand speed sensors and the plant-wide control network.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe chassis features a high-speed backplane that ensures perfectly synchronized data acquisition across all installed modules.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy facilitating centralized power distribution and robust signal isolation,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eit provides a high-integrity platform for continuous machinery surveillance and automated emergency shutdown protocols for critical rotating equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eStructural Framework and System Parameters\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eChassis Capacity\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e14 Universal Monitoring Slots plus dedicated Power and RIM slots\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eMounting Format\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e19-inch EIA Rack Mount (Option 01)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eStandard Compliance\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFully compliant with API 670 for Machinery Protection Systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eAgency Approvals\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eMulti-certified including ATEX,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIECEx,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand CSA (Option 02)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eSystem Redundancy\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupports dual power supply configurations to prevent single points of failure\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eCommunication Support\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDedicated slot for Rack Interface Module (RIM) or Transient Data Interface (TDI)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eHazardous Area Readiness\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with internal galvanic isolators and intrinsic safety barriers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003ePhysical Proportions\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e48.\u003c\/span\u003e\u003cspan class=\"\"\u003e2 cm x 26.\u003c\/span\u003e\u003cspan class=\"\"\u003e6 cm x 27.\u003c\/span\u003e\u003cspan class=\"\"\u003e4 cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eNet Weight\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e5.\u003c\/span\u003e\u003cspan class=\"\"\u003e95 kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eManufacturing Origin\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eUSA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"\"\u003eIndustrial Deployment and Site Applications\u003c\/h3\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eThis 14-slot 3500\/05 rack is the global industry standard for protecting high-capital machine trains,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eincluding steam turbines,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ecentrifugal compressors,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand large-scale pumps.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eIts modular architecture is predominantly deployed in the demanding environments of offshore oil platforms,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003epetrochemical refineries,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand thermal power stations where reliability is non-negotiable.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe chassis allows for hot-swappable module replacement,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eenabling maintenance teams to expand the system or replace components without interrupting the protection of active machinery.\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eBy isolating power management from sensitive signal-processing electronics,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe 3500\/05-01-01-05-00-01 maintains exceptional signal-to-noise ratios even in high-vibration and electromagnetic interference (EMI) prone industrial settings.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 class=\"\"\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: What is the benefit of the 14-slot universal configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe 14-slot capacity allows for a flexible mix of vibration,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003etemperature,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eseismic,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eand relay modules,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eproviding enough space to monitor complex machine trains from a single centralized chassis.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: Is the 3500\/05-01-01-05-00-01 compatible with redundant power supplies?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eYes,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003ethe two leftmost positions in the rack are specifically reserved for primary and redundant power supply modules to ensure continuous operation if one supply fails.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: Can this rack be installed in a hazardous area?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThis specific model supports ATEX and IECEx approvals,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003emaking it suitable for hazardous area protection strategies when integrated with the appropriate internal barriers or isolators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong class=\"\"\u003eQ: What is the purpose of the Rack Interface Module (RIM) slot?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"\"\u003eA:\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eThe RIM (or TDI) slot is the primary communication gateway for the rack,\u003c\/span\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eallowing the monitoring data gathered by the 14 universal slots to be transmitted to external software or control systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 5.95 kg weight include the modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, the 5.95 kg weight represents the empty 19-inch chassis. The total weight will increase as power supplies and monitoring modules are installed into the slots.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45832348074157,"sku":"3500\/05-01-01-05-00-01","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-3500-05-01-02-00-00-00-system-rack-yxdoe1pnvxo.jpg?v=1774492787","url":"https:\/\/www.maxwellplc.com\/products\/3500-05-01-01-05-00-01-bently-nevada-14-slot-19-inch-rack-chassis","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}