{"product_id":"330930-065-02-05-bently-nevada-3300-nsv-series-extension-cable","title":"330930-065-02-05 Bently Nevada 3300 NSv Series Extension Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330930-065-02-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for high-frequency signal transmission within 3300 NSv Machinery Protection Systems. The hardware maintains the electrical bridge link between a 3300 NSv proximity probe head and a matched Proximitor sensor, stabilizing loop impedance parameters to ensure precise eddy-current signal processing back to the monitor rack modules.\u003c\/p\u003e\n\u003ch3\u003eOptions Breakdown \u0026amp; Configuration Details\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330930\u003c\/strong\u003e: 3300 NSv Proximitor Extension Cable base part number\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-065\u003c\/strong\u003e: Cable length option (6.5 meters \/ 21.3 feet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-02\u003c\/strong\u003e: Connector and cable option (Miniature coaxial ClickLoc connectors with connector protectors)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-05\u003c\/strong\u003e: Agency approval option (Multiple regional hazardous area certifications for global industrial environments)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330930-065-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.24 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e220 mm x 220 mm x 45 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transmission component (0.0 mA loop draw)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Impedance Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm miniature coaxial design\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluorinated Ethylene Propylene (FEP) jacket execution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTermination Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGold-plated male and female ClickLoc coaxial fittings\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Bend Radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 inch) structural path routing constraint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Integrity\u003c\/h3\u003e\n\u003cp\u003eThe precision-extruded FEP coaxial layer governs internal capacitance parameters to prevent shifts in the 3300 NSv eddy-current probe scaling metrics. Field diagnostic evaluation requires verifying total loop tuning through standard gap voltage validation procedures, targeting a steady -10 VDC baseline reading across the active 60 mil linear span. The dense structural shield configuration suppresses high-frequency ambient noise interference, ensuring cross-talk suppression inside tight conduit layouts where adjacent multi-probe networks trace small-profile target areas and high-speed rotor dynamics.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info \u0026amp; Kit Inclusions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330930-065-02-05 3300 NSv Coaxial Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Factory-installed ClickLoc Coaxial Protection Boots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Compliance \u0026amp; Approvals Reference Manual Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003ePhysical installation requires strict adherence to minimal bend parameters to prevent micro-fractures in the coaxial line configuration.\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInspect the male and female ClickLoc coaxial terminal sockets. Clean any trace of oil or machining residue using an approved electronics volatile solvent.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the extension line terminal axially with the proximity probe lead. Press together firmly until the ClickLoc detent mechanism engages with an audible latch sensation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlide the integrated flexible connector protection boots directly over the mated joint to isolate the coaxial interface from fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the 6.5-meter line inside protective metal conduit. Enforce a physical installation bend pathway tracking above the 25.4 mm minimal bend radius limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTie down the coaxial run to prevent structural chafing. Ensure the outermost braided shield layer maintains complete electrical isolation from local machine frame ground potentials.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eLogistics Packaging Framework\u003c\/h3\u003e\n\u003cp\u003eDelivery time: 2-7 days when payment finish, routed via specialized international express logistics using DHL, FEDEX, or UPS. The passive coaxial runs are shipped wrapped in tight static-shielding rings inside sealed anti-static industrial packaging to maintain factory-calibrated impedance balances and prevent termination deformation during transit.\u003c\/p\u003e\n\u003ch3\u003eCoaxial System FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Can this 6.5-meter 3300 NSv extension cable be subbed into a standard 3300 XL 8 mm transducer loop?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal capacitance metrics of the 3300 NSv series cables are calibrated for the distinct electrical length profiles of the NSv family. Swapping this component into an 8 mm system shifts the overall loop impedance, destroying the 200 mV\/mil calibration matrix and triggering a NOT OK monitor loop fault.\u003c\/p\u003e\n\u003cp\u003eQ: Is this extension assembly hot-swappable at the Proximitor end while the processing rack is powered up?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Because the line handles low-energy sensor signals isolated by internal Proximitor current-limiting barriers, uncoupling the ClickLoc node while live does not induce component damage. The downstream rack tracking loop will register an immediate channel fault due to the broken circuit path.\u003c\/p\u003e\n\u003cp\u003eQ: Can multiple 330930 extension lines be linked in series to cover long field distances to a remote rack?\u003c\/p\u003e\n\u003cp\u003eA: No. Proximitor sensor calibration depends on a fixed total electrical path length, which must equal exactly 5.0 meters or 9.0 meters including the probe lead. Linking extension lines alters the designed circuit properties, rendering gap voltage calibration impossible.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518830731437,"sku":"330930-065-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330930-065-02-05-3300-nsv-extension-cable-ywaueyo5gom.jpg?v=1766979820","url":"https:\/\/www.maxwellplc.com\/products\/330930-065-02-05-bently-nevada-3300-nsv-series-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}