{"product_id":"330930-065-01-05-bently-nevada-nsv-extension-cable-3300-xl","title":"330930-065-01-05 Bently Nevada NSv Extension Cable 3300 XL","description":"\u003cp\u003eConfigured for signal transmission in proximity transducer systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330930-065-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNSv Extension Cable) provides direct physical and electrical connection between transducers and proximity monitors.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330930:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBase model series for NSv extension cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e065:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDefined length configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnector option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAgency approval and material specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330930-065-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.54 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.0 x 29.0 x 2.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMax 1 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe NSv extension cable is engineered to maintain signal integrity in rotating machinery monitoring. Eddy-current probe scaling must be verified during system installation to ensure proper output linearization. Technicians must perform gap voltage validation, targeting -10 VDC setpoints to confirm transducer response accuracy. Additionally, cable routing should prioritize cross-talk suppression by maintaining separation from high-voltage AC lines to prevent noise induction in the rotor dynamics signal path.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330930-065-01-05 Extension Cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective connector caps for environmental sealing during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical datasheet for integration and impedance matching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure M12 X 0.8 screw-type connectors manually; do not overtighten beyond finger-tight plus one quarter-turn.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure cable bends maintain a minimum radius to prevent stress on the internal conductor shielding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify that the shield drain wire is connected to the designated instrumentation ground to maintain noise immunity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure all mating connectors are clean and dry; utilize self-fusing silicone tape if the connection is exposed to high-humidity environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable interchangeable with 3300 XL standard series cables?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo. The NSv (Near-field) series features unique impedance characteristics and connector geometries specific to the NSv transducer system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow should I verify signal integrity?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePerform a static gap voltage check using a digital multimeter at the proximity monitor terminal strip with the system powered.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the cable require a specific bend radius?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, maintain a minimum bend radius of 25 mm to prevent potential damage to the internal coaxial signal conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I repair the connector?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField repair of the M12 connector is not recommended due to precision impedance requirements; replace the assembly if damage occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum operating current?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe cable assembly is rated for a maximum of 1 A; ensure the proximity monitoring system current draw remains within this limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAre there specific torque requirements?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnectors should be tightened to ensure the O-ring seal is compressed; excessive force may damage the nickel-plated brass threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I prevent signal interference?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRoute the extension cable through dedicated instrumentation conduit, away from power cabling or variable frequency drive output leads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cable compatible with all proximity monitors?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIt is optimized for the 3300 XL NSv Proximity Transducer System; check system manual for specific monitoring card compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378086666413,"sku":"330930-065-01-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330930-065-01-05-nsv-extension-cable-phqpmgfntm3.jpg?v=1764225449","url":"https:\/\/www.maxwellplc.com\/products\/330930-065-01-05-bently-nevada-nsv-extension-cable-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}