{"product_id":"330930-060-05-05-bently-nevada-3300-nsv-extension-cable","title":"330930-060-05-05 Bently Nevada 3300 NSv Extension Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330930-060-05-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable utilized to execute high-frequency RF signal transmission across 3300 NSv Proximity Transducer System platforms. It connects a 3300 NSv proximity probe directly to a matching Proximitor Sensor, conveying analog displacement data while preserving signal integrity without impedance mismatches.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330930\u003c\/strong\u003e: 3300 NSv Extension Cable base configuration identifier.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e060\u003c\/strong\u003e: Cable Length option (6.0 meters, 19.7 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Connector and Cable option (Standard coaxial cable fitted with miniature ClickLoc coaxial connectors, including silicone connector protectors).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Agency Approval option (Multiple multi-national hazardous area certifications including ATEX\/IECEx intrinsic safety standards).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330930-060-05-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.34 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22.0 cm x 22.0 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive electrical component (0.0 W structural power draw)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohms nominal coaxial matching profile\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e69.9 pF\/m (21.3 pF\/ft) nominal capacitance rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eArmor Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNon-armored, standard FEP outer jacket insulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Bend Radius\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.4 mm (1.0 in) static displacement boundary\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProximity Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 330930-060-05-05 extension cable maintains strict electrical parameters calibrated for the specific tuning profiles of 3300 NSv systems. In these configurations, the total electrical length of the proximity probe plus the extension cable must exactly match the system design specification (typically 5.0 or 7.0 meters total) to preserve factory eddy-current probe scaling.\u003c\/p\u003e\n\u003cp\u003eAltering the physical or electrical length of the transmission path introduces capacitive shifts that corrupt the gap voltage validation (-10 VDC targets) measured at the Proximitor Sensor output. Maintaining exact cable parameters prevents impedance variances, providing robust cross-talk suppression and stability when tracking fluid-film bearing changes under volatile rotor dynamics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this extension cable allow online hot-swap disconnection while the machine protective monitor loop is energized?\u003c\/p\u003e\n\u003cp\u003eA: Mechanically yes, but uncoupling the ClickLoc coaxial joint during operation breaks the RF tuning loop. This causes the associated 3500 module to immediately flag a Transducer Fault (NOT OK) condition. The channel must be placed in a bypassed state before manual disconnect.\u003c\/p\u003e\n\u003cp\u003eQ: Can a 3300 NSv extension cable be mixed with standard 3300 XL 8 mm proximity probe hardware components?\u003c\/p\u003e\n\u003cp\u003eA: No. The 3300 NSv series operates with a distinct electrical impedance and scaling profile compared to standard 3300 XL 8 mm systems. Intermixing these components causes massive calibration drift and compromises measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the silicone connector protectors included with the 05 connector option?\u003c\/p\u003e\n\u003cp\u003eA: The silicone boots slide over the mated ClickLoc coaxial junction to isolate the connection mechanically and electrically, preventing environmental moisture, oil, or conductive dust from penetrating the high-frequency joint.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Loop Length Compliance\u003c\/strong\u003e: Verify that the combined length of the proximity probe and the 330930 extension cable equals the required system length specified on the Proximitor Sensor label (e.g., 5.0-meter probe + 6.0-meter cable is invalid if the sensor expects a 7.0-meter total loop).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClickLoc Mechanical Engagement\u003c\/strong\u003e: Ensure all coaxial connections are clean and dry before mating. Push the male and female ClickLoc interfaces firmly together until they click into place. Do not use pliers or specialized wrenches, which can distort the thin-walled coaxial shell.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBend Radius Constraints\u003c\/strong\u003e: Do not crimp or sharp-bend the cable during installation. Maintain a minimum static bend radius of 25.4 mm (1.0 in) to prevent permanent deformation of the internal dielectric core.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConduit and Segregation Isolation\u003c\/strong\u003e: Route the extension cable inside dedicated, grounded metal conduit or junction boxes. Avoid running the line parallel to high-current AC power cables or variable frequency drive wires to optimize cross-talk suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSupply Manifest\u003c\/h3\u003e\n\u003cp\u003eThe standard package contains the following items:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e(1) Bently Nevada 330930-060-05-05 Extension Cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(2) Silicone connector insulation sleeves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e(1) Factory technical parameter sheet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eDistribution \u0026amp; Dispatch Profile\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDispatch Window\u003c\/strong\u003e: Shipped within 2-7 days when payment finish through verified institutional commercial accounts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCarrier Methods\u003c\/strong\u003e: Delivered globally via priority express networks, including DHL, FEDEX, or UPS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging Standard\u003c\/strong\u003e: Enclosed within a vacuum-sealed, specialized anti-static industrial packaging bag to safeguard the internal high-frequency dielectric insulation against moisture contamination and static damage during transport.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518867988653,"sku":"330930-060-05-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330930-060-05-05-3300-nsv-extension-cable-wysabgrl534.jpg?v=1766980582","url":"https:\/\/www.maxwellplc.com\/products\/330930-060-05-05-bently-nevada-3300-nsv-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}