{"product_id":"330930-060-00-cn-bently-nevada-extension-cable-3300-xl","title":"330930-060-00-CN Bently Nevada Extension Cable 3300 XL","description":"\u003cp\u003eConfigured for signal transmission between proximity probes and Proximitor sensors, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330930-060-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330930-060-00-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable) provides direct physical execution of low-loss coaxial signal routing within turbine monitoring (TSI) platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 330930-060-00-CN is structured according to Bently Nevada's 3300 XL transducer system standards:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330930: 3300 XL extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e060: Cable length (6.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Not applicable (Connector type).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCN: Agency approval (China CCC\/CNEx standards).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330930-060-00-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30.0 x 30.0 x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial (RFI\/EMI shielded)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGold-plated click-loc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Integrity and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThis extension cable is engineered to maintain system impedance consistency, which is critical for accurate eddy-current probe scaling. Because the 3300 XL system is calibrated as a set (Probe + Extension Cable + Proximitor), the cable length is integrated into the overall transducer response curve. The construction utilizes high-performance shielding for effective cross-talk suppression, ensuring that vibration signals remain isolated from ambient electromagnetic interference in high-velocity turbomachinery monitoring applications. Proper cable selection is necessary to maintain the -10 VDC target gap voltage and prevent signal attenuation in long-run installations.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330930-060-00-CN Extension Cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective connector caps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical compliance documentation (CNEx certified).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Extension cables must be matched to the system length calibration (e.g., 5-meter or 9-meter total system length).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Install cables in dedicated conduit or cable trays; keep them separated from high-voltage AC power lines to minimize inductive interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection: Ensure the click-loc connectors are fully engaged; use a firm, straight-line motion until the positive \"click\" is felt to ensure electrical continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection: Apply dielectric grease to connector threads in high-humidity or corrosive environments to prevent oxidation and contact resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrain Relief: Use appropriate strain relief clamps to prevent tension on the cable connectors, which can lead to center-pin misalignment or breakage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBend Radius: Adhere to the minimum bend radius specifications to avoid damaging the internal dielectric or shielding of the coaxial cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the length of the extension cable affect the calibration?\u003c\/p\u003e\n\u003cp\u003eYes. The 3300 XL system is calibrated for a specific total system length (usually 5 or 9 meters). Changing the cable length requires recalibrating the Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does the \"CN\" suffix indicate?\u003c\/p\u003e\n\u003cp\u003eThe \"CN\" suffix confirms the cable assembly meets China CCC and CNEx hazardous area certification requirements for local compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable compatible with legacy 3300 series probes?\u003c\/p\u003e\n\u003cp\u003eWhile physical connectors may match, 3300 XL cables are specifically engineered for the 3300 XL system; system-wide compatibility must be verified to ensure accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I cut this cable to a shorter length?\u003c\/p\u003e\n\u003cp\u003eNo. Altering the cable length will change the system impedance and frequency response, invalidating the factory calibration and degrading vibration data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I protect the connector threads?\u003c\/p\u003e\n\u003cp\u003eUse the provided protective caps during installation and keep the connectors clean; avoid using sharp tools near the gold-plated contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum operating temperature?\u003c\/p\u003e\n\u003cp\u003eThe cable is rated for continuous operation up to +177 deg C; ensure the routing path does not pass through areas exceeding this thermal limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable armored?\u003c\/p\u003e\n\u003cp\u003eThis specific model (330930-060-00-CN) is the standard configuration; check if your specific site requirements necessitate an armored variant for mechanical protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is a damaged cable identified?\u003c\/p\u003e\n\u003cp\u003eCommon signs include erratic \"Gap Error\" readings, noise spikes in the vibration signal, or a loss of signal continuity when the cable is flexed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518841118893,"sku":"330930-060-00-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330930-060-00-cn-3300-xl-standard-extension-cable-i5uxisepf1q.jpg?v=1766980235","url":"https:\/\/www.maxwellplc.com\/products\/330930-060-00-cn-bently-nevada-extension-cable-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}