{"product_id":"330908-00-55-05-02-00-bently-nevada-proximity-probes-3300-nsv-proximity-probes","title":"330908-00-55-05-02-00 Bently Nevada Proximity Probes 3300 NSv Proximity Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330908-00-55-05-02-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330908\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe, operates as a dedicated hardware component for non-contacting vibration and displacement measurements within 3300 NSv Proximity Transducer Systems. Designed for fluid-film bearing machines where target surfaces or installation clearances are highly constrained, this proximity probe executes direct mechanical-to-electrical signal transduction via proximity sensing methodologies.\u003c\/p\u003e\n\u003ch3\u003ePart Number Nomenclature Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe physical and mechanical configurations of the probe are determined via standard matrix selection parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUnthreaded Length Option (-00):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.0 in unthreaded length configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Case Length Option (-55):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5.5 in overall case length configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTotal Length Option (-05):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.5 m (1.6 ft) total cable length option.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector and Cable Option (-02):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMiniature coaxial ClickLoc connector, standard cable type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approval Option (-00):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNo specific hazardous area approvals specified.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Parameters \u0026amp; Dimensions\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330908-00-55-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150 mm x 150 mm x 50 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e303 stainless steel (SST)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohm coaxial, fluorinated ethylene propylene (FEP) insulated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 to 1.78 mm (10 to 70 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor (ISF)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil) typical\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer System \u0026amp; Cross-Talk Calibration\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv proximity probe utilizes advanced eddy-current probe scaling to ensure linear voltage responses across small-bore targets. When paired with the 3300 NSv Proximitor Sensor, proper field installation mandates gap voltage validation targeting a nominal -10 VDC baseline, aligning the probe within the optimized center of its linear range. Mechanical monitoring profiles are sustained through integrated cross-talk suppression mechanics, preventing electromagnetic interference from adjacent probes in dense rotor dynamics installations.\u003c\/p\u003e\n\u003ch3\u003ePackaging \u0026amp; Order Verification\u003c\/h3\u003e\n\u003cp\u003eUpon verified ordering, each shipment contains the following distinct hardware components:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Bently Nevada 330908-00-55-05-02-00 proximity probe assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Removable plastic connector protector sleeve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Factory calibration data matrix certification sheet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Instructions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDo not exceed a maximum installation torque rating of 3.4 N-m (30 in-lb) when mounting the probe case.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a minimum clearance of 5.0 mm between the probe tip and any adjacent structural steel walls to eliminate side-loading eddy current effects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute all coaxial extension cabling through grounded, dedicated structural conduit channels to secure the shielding matrix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the miniature coaxial ClickLoc connectors are completely free of oil and debris before executing final physical connection lockups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Logistics \u0026amp; Delivery\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEstimated Dispatch Window: 2-7 days when payment finish.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGlobal Carrier Services: Handled exclusively via DHL, FEDEX, or UPS air freight channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEquipment Packaging: Securely shipped inside anti-static industrial packaging with multi-layer high-density shock protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Engineering FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary indicators of a misaligned probe gap?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAn incorrect gap displays a static DC voltage outside the standard -9 VDC to -11 VDC operational window on the Proximitor output loop, requiring mechanical adjustment of the probe depth within its mounting bracket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this probe operate safely when fully submerged in industrial lubricating oils?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the polyphenylene sulfide tip and stainless steel case body are fully sealed against continuous fluid-film bearing oil exposure, maintaining structural and electrical isolation during deep well deployment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does a change in the target material affect the factory calibration matrix?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe system is factory-calibrated for AISI 4140 steel targets; using other materials alters the eddy-current probe scaling, which introduces errors requiring custom recalibration profiles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the minimum physical bend radius allowed for the probe cable run?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe flexible coaxial cable requires a minimum physical bend radius of 25.4 mm (1.0 in) to prevent permanent impedance structural damage to the 75 ohm internal shielding matrix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the integrated connector protected against field moisture ingress?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField installations require applying self-fusing silicone tape or installing dedicated connector protector kits over the ClickLoc union to prevent fluid contamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat occurs if the cross-talk suppression criteria are violated during mounting?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePlacing two probe tips closer than 30 mm causes high-frequency electromagnetic overlapping, introducing false beats and phantom components within the rotor dynamics vibration tracking signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this proximity probe model hot-swappable while the machinery train is live?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes, the probe contains no active digital processing nodes, allowing cold replacement or hot-swapping inside a live loop without causing damage to the paired Proximitor hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do temperature extremes alter the standard incremental scale factor?\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThermal exposure changes structural resistances, but thermal drift is constrained under 5% over the entire -35 deg C to +177 deg C window via internal analog compensation mechanics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518884798637,"sku":"330908-00-55-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330908-00-55-05-02-00-3300-nsv-proximity-probes-mrvxvxhzm1c.jpg?v=1766981025","url":"https:\/\/www.maxwellplc.com\/products\/330908-00-55-05-02-00-bently-nevada-proximity-probes-3300-nsv-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}